Owner's manual
916 NTCK16 Generic Central Office Trunk cards
Trunk to Trunk connection
When any disconnect supervision is configured (CLS = BAT, BTS), the
Loop Start Trunk of the Generic XFCOT is marked as having disconnect
supervision and therefore follows the same rules as a Ground Start Trunk.
There is no configuration involved for this operation.
Call disconnect
If any disconnect supervision is configured (CLS = BAT, BTS), the Loop
Start Trunk is released when the disconnect signal is received. This
applies also in call states such as ringing, camp-on, and DISA.
There is no configuration involved for this operation.
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008