Owner's manual

Trunk cards 75
If ALL is specified, all enabled loops (except attendant console
loops) and all shelves on each loop are tested.
If only one loop is being tested and it is disabled, enter ENLL
loop to enable and test a network card associated with the
specified loop. (This command cannot enable network cards
disabled by LD 32.)
If the system response is other than
OK, see Software
Input/Output Reference Administration (NN43001-611) to
analyze the messages.
3 End the session in LD 30:
****
--End--
Trunk cards
Use the following procedures to test a trunk card.
Procedure 9
Testing a trunk card using a maintenance telephone
Step Action
1 Access the system from a maintenance telephone.
See "Communicating with the Meridian 1" in the Software
Input/Output Reference Administration (NN43001-611) for
details on accessing the system from a maintenance telephone.
2 Test the trunk unit:
LD 36
TRKlsculoop, shelf, card, and unit numbers
3 If the maintenance telephone is hooked up to a monitor and the
system response is other than OK, see Software Input/Output
Reference Administration (NN43001-611) to analyze the
messages.
--End--
Procedure 10
Testing a trunk card using a system terminal
Step Action
1 Log into the system:
LOGI (password)
2 Enter:
LD 36
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008
Copyright © 2003-2008 Nortel Networks
.