Operation 541
Figure 162
Two-way, loop DR, TIE trunk call connection sequence - incoming call from far-end PBX
In an incoming call configuration, the far-end initiates a call by placing
a low-resistance loop across the tip and ring leads. See Figure 171
"Two-way, loop DR, tie trunk call states - incoming call from far-end PBX"
(page 551) and Figure 172 "Two-way, loop DR, tie trunk call connection
sequence - incoming call from far-end PBX" (page 552) on. This causes
a current to flow through the battery feed resistors in the trunk circuit.
Address signaling is then applied by the far-end in the form of DTMF tones