Owner's manual
210 NT5D11 and NT5D14 Lineside T1 Interface cards
For the MMI terminal to be able to communicate to the Lineside T1 card,
the interface characteristics must be set to the following:
•
Speed – 1200 or 2400 bps, depending on the setting of switch position
1 of Switch 1
• Character width – 8 bits
• Parity bit – none
•
Stop bits – one
• Software handshake (XON/XOFF) – off
Software configuration
Although much of the architecture and many of the features of the Lineside
T1 card differ from the analog line card, the Lineside T1 card has been
designed to emulate an analog line card to the CS 1000 software.
Because of this, the Lineside T1 card software configuration is performed
the same as two adjacent analog line cards.
All 24 T1 channels carried by the Lineside T1 card are individually
configured using the Analog (500/2500-type) Telephone Administration
program LD 10. Use Table 87 "DX-30 to T1 time slot mapping" (page
210) to determine the correct unit number and the technical document
Software Input/Output Reference — Administration (NN43001-611) for LD
10 service change instructions.
The Lineside T1 card circuitry routes 16 units (0-15) on the motherboard
and eight (0-7) units on the daughterboard to 24 T1 channels. The
motherboard circuit card is located in the left card slot, and the
daughterboard circuit card is located in right card slot. For example, if
the Lineside T1 card is installed into card slots 0 and 1, the motherboard
would reside in card slot 0 and the daughterboard would reside in card
slot 1. In order to configure the terminal equipment through the switch
software, the T1 channel number must be cross-referenced to the
corresponding card unit number. This mapping is shown in Table 87
"DX-30 to T1 time slot mapping" (page 210).
Table 87
DX-30 to T1 time slot mapping
Item TN
T1 Channel Number
Motherboard
01
Motherboard
12
Motherboard
23
Motherboard
34
Nortel Communication Server 1000
Circuit Card Reference
NN43001-311 02.06 Standard
27 August 2008