Preparing the LMF – continued
FEB 2005 1X SC 4812T Lite BTS Optimization/ATP 3-13
PRELIMINARY
Creating a Named
HyperTerminal Connection for
MMI Communication
Confirming or changing the Configuration Data of certain BTS Field
Replaceable Units (FRU) requires establishing an MMI Communication
Session between the LMF and the FRU.
Using features of the Windows Operating System, the connection
properties for an MMI Session can be saved on the LMF Computer as a
named Windows HyperTerminal Connection. This eliminates the need
for setting up Connection Parameters each time an MMI Session is
required to support Optimization.
Once the named connection is saved, a shortcut for it can be created on
the Windows Desktop. Double–clicking the Shortcut Icon will start the
connection without the need to negotiate multiple menu levels.
Perform the procedure in Table 3-4 to establish a named HyperTerminal
Connection and create a Windows Desktop Shortcut for it.
Table 3-4: Create HyperTerminal Connection Procedure
n Step Action
1 From the Windows Start Menu, select:
Programs>Accessories>
2 Perform one of the following:
For Windows NT, Windows 2000, or Windows XP, select Hyperterminal and then click on
HyperTerminal.
For Windows 98, select Communications, double click the Hyperterminal Folder, and then
double click on the Hyperterm.exe Icon in the window that opens.
S If a Location Information Window appears, enter the required information, then click on the
Close Button.
This is required the first time, even if a modem is not to be used.
S If a message saying “You need to install a modem.....” appears, click on NO.
3 When the Connection Description Box opens, perform the following actions:
3a Type a name for the connection being defined (e.g., MMI Session) in the Name: Window.
3b Highlight any icon preferred for the named connection in the Icon: Chooser Window.
3c Click OK.