User Manual

InService Calibration continued
Jan 2002
G-17
SC4812ET BTS Optimization/ATP CDMA LMF
Table G-5: InService Calibration
Step Action
! CAUTION
Perform the Inservice Calibration procedure on OOS devices only.
8 Select the desired test:
Select the target BBX(s) on the CCCP cage picture.
Click Tests>[desired test] from the menu bar at the main window.
Select the target carrier and confirm the channel number in the pop up window.
Leave the Verify BLO check box checked.
From the Test Pattern pick list, select a test pattern.
Click the OK button to start calibration.
Follow the onscreen instructions, except, do not connect to the BTS antenna port, connect to the
directional coupler (fwd) port associated with the on screen prompt antenna port.
NOTE
Selecting Pilot (default) performs tests using a pilot signal only.
Selecting Standard performs tests using pilot, synch, paging and six traffic channels. This requires
an MCC to be selected.
Selecting CDFPilot performs tests using the CDF value for pilot gain and IS97 gain values for all
the other channels included in the Standard pattern setting (paging, synch, and six traffic). Using
this pattern setting requires the selection of both a BBX and at least one MCC.
Selecting CDF performs tests using pilot, synch, paging and six traffic channels, however, the gain
for the channel elements is specified in the CDF file.
9 Save the result and download the BLO data to the target BBX(s):
Click the Save Result button on the result screen.
The window closes automatically.
10 Logout from the BTS and close the LMF session:
Click BTS>Logout to close the BTS connection.
Close the LMF window.
11 Restore the new bts*.cal file to the CBSC.
12 Enable the target device(s) from the CBSC.