User Manual

Troubleshooting: Transmit ATP continued
Jan 2002
6-9
SC4812ET BTS Optimization/ATP CDMA LMF
Table 6-12: Troubleshooting Rho and Pilot Time Offset Measurement Failure
ActionStep
5 Verify that no LPA in the sector is in alarm state (flashing red LED). Reset the LPA by pulling
the circuit breaker, and, after 5 seconds, pushing back in.
6 If Rho value is unstable and varies considerably (e.g. .95,.92,.93), this may indicate that the
GPS is still phasing (i.e. trying to reach and maintain 0 freq. error). Go to the freq. bar in the
upper right corner of the Rho meter and select Hz. Press <Shiftavg> and enter 10, to obtain an
average Rho value. This is an indication the GPS has not stabilized before going INS and may
need to be re-initialized.
Cannot Perform Code Domain
Power and Noise Floor
Measurement
Follow the procedure in Table 6-13 to troubleshoot code domain and
noise floor measurement failure.
Table 6-13: Troubleshooting Code Domain Power and Noise Floor Measurement Failure
Step Action
1 Verify presence of RF signal by switching to spectrum analyzer screen.
2 Verify PN offset displayed on analyzer is same as PN offset being used in the CDF file.
3 Disable and re-enable MCC (one or more MCCs based on extent of failure).
Cannot Perform Carrier
Measurement
Follow the procedure in Table 6-14 to troubleshoot carrier measurement
failure.
Table 6-14: Troubleshooting Carrier Measurement Failure
Step Action
1 Perform the test manually, using the spread CDMA signal. Verify High Stability 10 MHz
Rubidium Standard is warmed up (60 minutes) and properly connected to test set-up.
6