User Manual

Troubleshooting68P09255A57-2
Aug 2002
SC4812ET Optimization/ATP Manual Software Release R16.1.x.x
PRELIMINARY
6-11
GLI3 Ethernet A and B Connections
These BNC connectors are located on the C-CCP backplane and routed
to the GLI3 board. This interface provides all the control and data
communications between the master GLI3 and the other GLI3, between
gateways, and for the LMF on the LAN.
BBX2 Connector
Each BBX connector consists of a Harting 2SU/1SU digital connector
and two 6-conductor coaxial connectors. These connectors provide DC,
digital, and RF inputs/outputs for the BBXs in the C-CCP backplane.
CIO Connectors
RX RF antenna path signal inputs are routed through RX Tri-Filters
(on the I/O plate), and via coaxial cables to the two MPC modules -
the six A (main) signals go to one MPC; the six B (diversity) to
the other. The MPC outputs the low-noise-amplified signals via the
C-CCP backplane to the CIO where the signals are split and sent to
the appropriate BBX.
A digital bus then routes the baseband signal through the BBX, to the
backplane, then on to the MCC slots.
Digital TX antenna path signals originate at the MCC24s. Each
output is routed from the MCC slot via the backplane appropriate
BBX.
TX RF path signal originates from the BBX, through the backplane to
the CIO, through the CIO, and via multi-conductor coaxial cabling to
the LPAs in the LPA shelf.
C-CCP Backplane Troubleshooting Procedure
The following table provides a standard procedure for troubleshooting
problems that appear to be related to a defective C-CCP backplane. The
table is broken down into possible problems and steps which should be
taken in an attempt to find the root cause.
NOTE
It is important to note that all steps be followed before replacing
ANY C-CCP backplane.
Digital Control Problems
No GLI3 Control via LMF (all GLI3s)
Follow the procedure in Table 6-16 for problems with GLI3 control.
Table 6-16: No GLI3 Control via LMF (all GLI3s)
Step Action
1 Check the ethernet for proper connection, damage, shorts, or opens.
2 Verify C-CCP backplane Shelf ID DIP switch is set correctly.
3 Visually check the master GLI3 connector (both board and backplane) for damage.
4 Replace the master GLI3 with a known good GLI3.
6