User Manual

Alarms Testing continued
SC4812ET BTS Optimization/ATP CDMA LMF
Jan 2002
3-114
Rectifier Over Temperature
Alarm
This is connector J8 on the rear of the Meter Alarm Panel
itself, this is not connector J8 on the connector bulkhead at
the rear of the cabinet.
NOTE
Table 3-63 gives instructions on testing the battery over temperature
alarm system.
Table 3-63: Rectifier Over Temperature Alarm
Step Action
1 Remove the J8 link on the rear of the Meter Alarm Panel (see Figure 3-25 for J8 location).
NOTE
This is the J8 on the rear of the Meter Alarm Panel itself, this is not connector J8 on the connector
bulkhead at the rear of the cabinet.
2 Verify that RECTIFIER OVERTEMP LED (red) is lite. Contacts on K1 and K2 change states (K1
now closed and K2 open).
3 Verify that the LMF has reported an alarm condition. (BTS #26)
4 Reinstall J8 connector and verify that all alarm conditions have cleared. K1 and K2 should now be in
their normal states (K1 open and K2 closed).
5 This completes the system tests of the SC 4812ET power cabinet.
3