User's Manual

4 Applications
68 Spectra Precision Focus 4 Total Station User Guide
To reset the horizontal angle, enter a value in the HA field and then press
[ENT].
If you do not need to reset the horizontal angle, leave the HA field blank
and then press
[ENT].
The Stn Setup menu appears.
Remote BM
Select this option to determine the station elevation.
1. Press
[4] or select Remote BM from the Stn
Setup menu.
2. Enter the BM point and press
[ENT]. The point
appears briefly. The cursor then moves to the HT field.
3. Enter the HT and then press
[ENT].
4. Sight the Bench Mark point and then press
[MSR1]
or
[MSR2].
The updated station coordinates are displayed.
You can change the HI in this screen.
5. To record the updated STN, press
[ENT].
When the HI setting is changed, the Z coordinate is
updated before the station is recorded.
You must complete a station setup before you use the Remote Benchmark function.