Installation

3. TEST INSTALLED FAUCET
· T
urn on water supply. Rotate the hot handle and hold until the tank fills up, (tank is full when water comes
out of the spout). Rotate hot handle to turn water off.
· Check all connections for leaks. Make any final adjustments as required by first turning off the water
supply to relieve the pressure.
· Plug in the water tank and wait between 10-15 minutes for water to reach its target temperature.
ATTACHING WATER CONNECTIONS TO SUPPLY AND TANK (See Fig 2)
Figure 2
Blue tube
(See Note)
Red tube
Grey tube
Tank inlet
Brass coupling
Inlet coupling (supplied
with heater tank)
Tank outlet
Hot water Tank
#5-036
2001 CARNEGIE AVE, SANTA ANA CA 92705
(949) 417-5207
WWW.NEWPORTBRASS.COM
NWP-106 Rev G
EN-4414
10/27/2021
9/16" thread
fitting
Water supply
(not included)
· Connect blue tube to the cold water supply utilizing the 9/16 thread fitting.
· Note: Do not trim blue tube and use it with 1/4" compression fitting. Blue hose can only be trimmed if it is
used with a quick-connect fitting that is supplied with Newport Brass heater tank.
· Trim the grey hose as short as possible to reduce back pressure, then, connect to the center outlet tube on
the top of the tank utilizing the brass coupling.
Trim and connect the red tube to heater tank utilizing a quick-connect fitting with filter (supplied with
heater tank). Debris screen filter protects heater tank from blockages. Warranty will be void if quick-