Instruction Manual Power plug Thank you for your support ⚫ Please read the instruction manual carefully before operating ⚫ Please keep the instruction manual for further reference Shenzhen NEO Electronics Co.
Product Introduction SmartPlug is a universal, Z-Wave™ Plus compatible and relay switch in the form of a socket adapter. The device may be used to operate any device up to 3000w power output. The device features voltage, current, active power and power consumption measuring. This product can be included and operated in any Z-Wave™ network with other Z-Wave™ certified devices from other manufacturers and/or other applications.
⚫ ⚫ Electricity metering can be used to calculate electricity consumption Over current protection can be used more safely
Product Configuration Product List ⚫ ⚫ Power plug 1pc Instruction manual 1pc pins The code button LED light slot Z-Wave™ Network Inclusion/Exclusion/Reset There is one button on the side of the device, it can be executed inclusion, exclusion and reset from Z-Wave™ network. Blue led will blink with 1、 Power up the device. interval until 2 、 Set Z-Wave™ Controller into inclusion 1s inclusion successful.
inclusion mode. Notice 2: Factory Reset will clear the device all Z-Wave™ Network data (include home id, node id, etc…) saved in memory, and restore all configuration parameters to factory default. Please use this procedure only when the network primary controller is missing or otherwise inoperable.
Tips ⚫ ⚫ ⚫ ⚫ Please do not spray water on the power plug. The on and off of power plug can be switched remotely by mobile phone APP. The load connected with the power plug shouldn’t exceed 2500w to avoid damaging the power plug. Make sure of that power plug is in the z-wave network. Association The device supports 2 association groups, and each group supports max 5 associated nodes.
OFF COMMAND_CLASS_SWITCH_BINAR SWITCH_BINARY_S 0x00 Y ET COMMAND_CLASS_BASIC BASIC_SET 0x00 Electrical Parameters Measuring The device provides line voltage (V), loaded current (A), active power (W), and accumulated energy consumed (kWh) measurement; the significant digits of the measured result should be two digits after the decimal point; These electrical parameters result will be reported to the Z-Wave™ controller regularly through the Meter Report of Meter Command Class, the interval of which can be c
Timer The device also provides the function of timing, and users can turn off the outlet by opening this function and setting the time cycle, the setting method of which is shown in "Configuration: No.4 and Configuration No 11".
6) Meter Report Enable This configuration sets the meter report function enabled or disabled. ‘0’ – Disable meter report function. ‘1’ – Enable meter report function with time interval defined by “Configuration No. 11”. When device is detected an OCP event or the relay turned on or turned off, device still will report all meter values once if this value be set to ‘0’.
Number 11 ● 2 0 ~ 30000 300 To Simulate Over Current Protection Function, First User Must Turn on SmartPlug And Then Write 1 Byte Data 0xFF(255) to Parameter Number 99. SmartPlug will Be Turned Off And Report Alarm Messages to Hubs. Meantime Red Led Will Blink with 1s Interval.
communicate, otherwise the device will not response any commands.
Led Color Indicator Led Color Red Green Blue Yellow Action Description Light On 1s When Power On Blink One Time Light On 1s Blink With 1s Interval Light On 1s When Power On Light On 1s Light On Always Blink with 1s Interval Blink with 500ms Interval Not Add in Z-Wave Network Light On Always Sensor Measuring Time Press And Hold Button 10s, Off at 11th Second Over Current Detected, SmartPlug Turn Off.