REPLACING THE BATTERIES
The lifetime of the 2x 1.5V AA alkaline batteries is about 40 hours of continuous use.
The batteries can be replaced by a new set of batteries. For this the housing has to
be opened, first remove the 4 screws at the front plate.
Figure 18: Configuration tool remove screws to open housing
Now the front plate including the electronics can be removed out of the housing.
Disconnect the reader antenna before you can completely remove the front
including the batteries and electronics.
Figure 19: Configuration tool: Battery replacement
Before the batteries can be removed the rubber strap has to be loosened. Replace
the empty batteries with 2 new 1.5V AA-type alkaline batteries, make sure the
polarity is correct. Reinstall the rubber strap and reconnect the reader antenna
before you close the housing again.
4-screws
Note
Be careful when you open
the housing and make sure
the RFID antenna is
disconnected before you
completely open the
housing to replace the
batteries.