User's Manual Part 4
ROI-S05752 Maintenance
-35-
RF SUB Band Select
15 Click on the menu button, select required Sub-Band from pull-
down menu, and click on the “Set” button,
Note: This is an offline menu item to be carried out after a Sub-Band
BPF change in the ODU. Refer to Appendix RF Frequency Plan
in section 1 for details of Sub-Band versus Frequency Range.
Antenna Alignment Mode
16 Click on the setting button “On”, and click on the “Set” button,
to apply Antenna Alignment Mode ( ), then, value field turns to
“On”,
Notes: 1 The setting “On” is applied for antenna orientation or
RX LEV reading when using NLITE E Monitor unit.
2 For the antenna orientation, set the TX power to the
required level by ATPC Manual Control or MTPC mode
at the opposite site.
3 The Antenna Alignment Mode is used for extending the
dynamic range of the NLITE E Monitor unit. In order to
measure in high range of AGC V, it is mandatory
required to set Antenna Alignment Mode to ON. If not
set to ON, the indicated AGC voltage is not guaranteed
value.
4 No. 1 and No. 2 apply for 1+1 configuration.