V1.1-M 10Apri2020 User Manual WARNING Read carefully and understand all ASSEMBLY AND OPERATION,INSTRUCTIONS before operating. Failure to follow the safety rules and other basic safety,precautions may result in serious personal injury.
T an you for c oosin a Nature Po er Pro uct This product is designed for certain applications only. The distributor cannot be responsible for issues arising from modification. We strongly recommend this product not be modified and/or used for any application other than that for which it was designed. If you have a question relative to a particular application, do not use the product until you have first contacted the distributor to determine if it can or should be performed on the product.
IMPORTANT SAFETY INSTRUCTIONS 1. GENERAL SAFETY PRECAUTIONS Warning! Before using the Inverter, read the safety instructions. 2. This manual contains important safety and operating instructions for power inverter 1000W. This manual will show you how to use your inverter safely and effectively. Please read, understand and follow these instructions and precautions carefully. 3. Do not expose the inverter to rain, snow, spray or dust.
horizontal. 12. Do not operate the inverter close to combustible gas or open fire. 13. Do not operate appliances that may feed power back into the inverter. 14. Important: Do not use in a marine application. 15. Do not disassemble the unit; take it to a qualified serviceman when service or repair is required. Incorrect reassembly may result in a risk of electric shock or fire. 16. To reduce risk of electric shock, unplug unit from outlet before attempting any Page maintenance or cleaning.
FEATURES • High-speed cooling fan To keep the inverter cool, the fan turn on depend on the load on the inverter or temperature in the inverter. The fans do not run when the inverter is turned off. • Positive Battery Cable Terminal (Red) • Negative Battery Cable Terminal (Black) • ON/OFF rocker switch • LED indicator Green indicates Power ON Red indicates Overload/Interruption in power • 12 Volt power cord • 120V standard AC outlets (2) • USB port(s) – 5V, 2.
Vehicle: Connect to the chassis, unpainted frame part, or engine block of the vehicle. Fixed location: Connect to a ground rod or other appropriately rated ground. Warning! Make sure that all the DC connections are tight. Loose connections could result in overheating and can be a potential hazard. CONNECTING INVERTER CABLES TO THE INVERTER 1. Locate the Positive and Negative terminals on the inverter. Page 2. From the POSITIVE (RED) and the NEGATIVE (BLACK) terminals, remove 3.
NOTE:Please use the cables we provided, DON'T use battery clamps.
OPERATING INSTRUCTIONS 1. Connect the inverter (see Connecting Inverter Cables section. 2. Switch the inverter’s ON/OFF switch to the ON (I) position. 3. The GREEN LED indicator will light, indicating the inverter is receiving power. 4. Switch the inverter’s ON/OFF switch to the OFF (O) position. (The 6. Plug the device into the inverter’s AC outlet. 7. Switch the inverter’s ON/OFF switch to the ON (I) position. 8. Turn the device on. 9. To disconnect, reverse the above procedure.
POWER SOURCE Your average automobile battery at full charge will provide an ample power supply to the inverter when the engine is on. Keep the car running at all times when using the inverter. The actual length of time the inverter will function depends on the age and condition of the battery and the power demand being placed by the device being operated with the inverter. When possible, recharge your batteries when they are not more than 50% discharged.
LED INDICATOR AND SHUTDOWN PROTECTION The Green LED lights automatically when the inverter is plugged into a 12 volt DC power source and is turned on. The Red LED lights, the alarm sounds and the inverter automatically turns itself off under the following conditions: 1. When the power input from the vehicle’s battery drops to approximately 10.5 volts, the low voltage alarm will sound. When the voltage goes down below 10 VDC, the inverter shuts off. Recharge or replace the battery. 2.
IF THE INVERTER’S FUSE BLOWS i which should not have to be replaced under normal operating conditions. A blown fuse is usually caused by reverse polarity or a short circuit within the device or equipment being operated. If a fuse does blow, take the inverter to MAINTENANCE AND STORAGE INSTRUCTIONS 1. Before each use, ensure that all of the inverter’s components are in place and in good working condition. 2. After use and before performing maintenance, unplug and disconnect the inverter. 3.
TROUBLESHOOTING PROBLEM Low or no output voltage. Red LED is lit. POSSIBLE CAUSE Poor contact at terminals OVP/OLP. REASON/SOLUTION Disconnect and reconnect the 12V connections. Using incorrect type of voltmeter Use a true RMS reading meter. to test output voltage. The battery voltage is below Recharge or replace the battery. 10 volts. The equipment being operated is Use a higher capacity inverter or drawing too much power.
SPECIFICATIONS Nominal input voltage ................................................................................. 12.8-13.2 VDC Nominal output voltage ................................................................................115±10% VAC Output frequency .................................................................................................. 60±3 Hz Operating input voltage .............................................................................. 10.0-15.
LIMITED WARRANTY Nature Power warrants our products to the original purchaser that this product is free from defects in materials and workmanship for the period of one year from date of purchase. In the case of product defect, contact Nature Power customer service to receive troubleshooting. If defective part or unit should be returned, a Return Authorization Number must be issued by Nature Power and the defective part or unit should be returned to the authorized location at the purchasers’ expense.