3.0 INSTALLATION
3.1 LEVELLING THE APPLIANCE
68.4B
Cleanoutashesfromtheinsideofthewood-burningappliance.Makesurethatthechimneyandwood-burning
applianceareinacleanandsoundconditionandconstructedofnon-combustiblematerials.Ifnecessaryhave
anyrepairworkdonebyaqualifiedpersonbeforeinstallingtheinsert.Removetheexistingappliancedamper
orlockintoanopenposition.
Usingscrews,attachtheappliancewarningtag
totheinsideofthefireboxoftheapplianceinto
whichtheinsertisbeinginstalled.
Thesheet-metalpartsoftheappliance,inwhich
thegasapplianceinsertistobeinstalled,must
notbecut.
Ifthewood-burningfactory-builtappliancehas
nogasaccesshole(s)provided,anaccessholeof1½inch(38.1mm)orlessmaybedrilledthroughthelower
sidesorbottomoftheapplianceinaproperworkmanlikemanner.Thisaccessholemustbepluggedwithnon-
combustibleinsulationafterthegassupplylinehasbeeninstalled.
Ensurethatexistingchimneycleanoutsfitproperly.
Therefractory,glassdoors,screenrails,screenmeshandloggratesmayberemovedfromtheexisting
appliancebeforeinstallingthegasapplianceinsert.
Smokeshelves,shieldsandbafflesmayberemovedifattachedbymechanicalfasteners.
Theventilationopeningsintheexistingappliancemaybeobstructedbythebackerplates,aluminiumtrimetc.
butthesepartsarenottobeappliedsoastohaveanairtightseal.
!
WARNING
RISK OF FIRE, MAINTAIN SPECIFIED AIR SPACE CLEARANCES TO VENT PIPE AND APPLIANCE.
WOLF STEEL
DIMS:INCHES
TITLE: FIREPLACE WARNING TAG - ULC S628
DWG #: W385-0199
DATE: 07.25.00
CLASS IIA-2 LABEL
2
1
/
2
" x 6" C/W 2 HOLES 0.188" DIAMETER
BLACK LETTERING ON WHITE ALUMINUM
WARNING LETTERING TO BE NO LESS THAN 0.240"
OTHER LETTERING TO BE NO LESS THAN 0.120”
CDIZC / GDIZC
W385-0199_B
REVISION: A: 02.02.07 II ADD NOTE B: 01.15.08 II ADD SPANISH_RICH
WARNING: THIS FIREPLACE HAS BEEN CONVERTED FOR USE WITH A GAS FIREPLACE
INSERT ONLY AND CANNOT BE USED FOR BURNING WOOD OR SOLID FUELS UNLESS ALL ORIGINAL
PARTS HAVE BEEN REPLACED AND THE FIREPLACE IS RE-APPROVED BY THE AUTHORITY HAVING
JURISDICTION.
ATTENTION: CE FOYER A ETE CONVERTI AFIN D’ETRE UTILISE SEULEMENT
COMME FOYER ENCASTRE AU GAZ ET NE PEUT ETRE UTILSE POUR BRULER DU BOIS OU
TOUT AUTRE COMBUSTIBLE SOLIDE, SANS QUE TOUTES LES PIECES ORIGINALES AIENT
ETE REMPLACEES ET QUE LE FOYER SOIT APPROUVE DE NOUVEAU PAR LES AUTORITES
AYANT JURIDICTION.
ADVERTENCIA: ESTA CHIMENEA SE REMODELÓ PARA USARSE SOLO CON UNA
INSERCIÓN DE CHIMENEA A GAS Y NO PUEDE USARSE PARA QUEMAR MADERA NI COMBUSTIBLES
SÓLIDOS, A MENOS QUE SE HAYAN REEMPLAZADO TODAS LAS PIEZAS ORIGINALES, Y LA AUTORI-
DAD JURISDICCIONAL LA HAYA VUELTO A APROBAR.
Movetheapplianceclosetoitsfinalposition.Thisapplianceisequippedwithlevellingscrewslocatedonthe
base.Levelusingthelevellingscrews.Levellingtheappliancewilleliminaterockingorexcessivenoisewhen
thefanisinoperation.Oncetheapplianceislevel,moveitpartiallyintoplacetoallowforallconnectionstobe
made.Itisnotpracticaltoleveltheapplianceonceithasbeeninstalled.Determinetherequireddepthpriorto
installingtheapplianceandadjustthelevellingscrewsaccordingly.
67.2