26690 Kickspace Manual for web_Layout 1 24/09/2013 10:07 Page 2 KICKSPACE® 500, 600, 600-12V & 800. INSTALLATION, OPERATING, MAINTENANCE AND AFTER SALES MANUAL. Product Serial Number: Please leave this manual with the end user. Part Number: 1370054 01.01.2013 ISSUE 6 heatingthroughinnovation.
6690 Kickspace Manual for web_Layout 1 24/09/2013 10:07 Page 3 KICKSPACE ® 500, 600, 600-12V & 800 02 Contents 1.0 Safety Information 02 8.0 Water Connection 06 2.0 General Information 03 9.0 Electrical Connection 07 3.0 Heating System Design 03 10.0 Technical Data 08 4.0 Selection and Sizing for Heating 03 11.0 Operating Instructions 09 5.0 Location 04 12.0 Troubleshooting 10 6.0 Preparation 04 13.0 Maintenance 11 7.0 Fitting the KICKSPACE ® 05 1.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:07 Page 4 KICKSPACE ® 500, 600, 600-12V & 800 Children of less than 3 years should be kept away from the unit unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on / off the appliance provided that it has 2.0 been placed or installed in its normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:07 Page 5 04 KICKSPACE ® 500, 600, 600-12V & 800 5.0 Location l This KICKSPACE ® unit is designed for installation in the cavity beneath cupboards in kitchens or other similar locations on the vacant floor space. l When installed in a kitchen consideration should be given to storage of perishable goods in the cupboard above. l A minimum of 25mm clear headroom is required above the top of the KICKSPACE® when fitted.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:08 Page 6 KICKSPACE ® 500, 600, 600-12V & 800 05 7.0 Fitting the KICKSPACE ® l Position the KICKSPACE® under the cupboard in the required location, with the front edge just behind the line of the plinth. l Ensure that the flexible hoses are not kinked and that the electrical cord is not in contact with hot surfaces. l Replace the plinth and bring the KICKSPACE ® forward into the opening so the front edge projects 8mm through the plinth (see Fig. 2).
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:08 Page 7 06 KICKSPACE ® 500, 600, 600-12V & 800 8.0 Water Connection Pipework must be positioned correctly to ensure flexible hoses are not kinked when installed (see Figs. 5a & 5b). Only use the hose sets supplied with this unit. Do not use old or alternative hose sets. WALL WALL 250 300 400 100 Fig. 5a Left hand view - suggestion only Fig. 5b Right hand view - suggestion only l Connect valve ends of the flexible pipes to the KICKSPACE ®.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:08 Page 8 KICKSPACE ® 500, 600, 600-12V & 800 07 9.0 Electrical Connection l The electrical installation must comply with local or national wiring regulations. l Remote Control Switch - A remote control switch is available as an accessory, and if required should be wired at this stage. l This unit is supplied fitted with a 2 metre 0.75mm2 cord.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:08 Page 9 08 KICKSPACE ® 500, 600, 600-12V & 800 9.0 Electrical Connection (continued...) Transformer L MOTOR Mains Supply 240V br N bl br Fan Selector Switch bl Connector Block Summer/Winter Switch LOW LIMIT THERMOSTAT Fig. 9 KICKSPACE® 600-12V wiring diagram 10.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:08 Page 10 KICKSPACE ® 500, 600, 600-12V & 800 10.0 Technical Data 09 (continued...
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:08 Page 11 10 KICKSPACE ® 500, 600, 600-12V & 800 12.0 Troubleshooting installer or MYSON Service. Before calling your installer or MYSON Service, please carry out the checks listed below. Once installed this fan convector becomes an integral part of a complete heating system that includes boiler, pump, other emitters such as radiators and fan convectors, and a number of heating controls, dependent on system complexity.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:08 Page 12 KICKSPACE ® 500, 600, 600-12V & 800 11 13.0 Maintenance Before undertaking any maintenance activity isolate the electrical supply. Maintenance should be restricted to occasional removal of dust and lint around the front grille. This should involve internal cleaning of the heat exchanger using a soft brush or vacuum cleaner, taking care not to damage fan or heat exchanger. Please see after sales service details on the back cover.
26690 Kickspace Manual for web_Layout 1 24/09/2013 10:07 Page 1 MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk Product code and serial number location After Sales Service: MYSON Service, Somerden Road, Hull, East Yorkshire HU9 5PE T: 01482 713927, F: 01482 789056, service.convectors@myson.co.uk Spare parts and technical help on all Convector products are available from MYSON Service. 01.01.