23674 HiLine Super RC manual 27/06/2011 09:24 Page 2 Installation, Operating, Maintenance and After Sales Manual. HI-LINE Super RC Models: 25-18, 29-20 heatingthroughinnovation. 01.06.2011 ISSUE 4 Product Serial Number: Please leave this manual with the end user.
3674 HiLine Super RC manual 27/06/2011 09:24 Page 3 Contents 1.0 General Information 03 2.0 Heating System Design 03 3.0 Unit Selection/Sizing 03 4.0 Location 03 5.0 Preparation 04 6.0 Fixing 04 7.0 Water Connections 05 8.0 Electrical Connection 06 9.0 Commissioning Procedure 07 10.0 Technical Data 08 11.0 Operating Instructions 09 12.0 Troubleshooting 10 13.
23674 HiLine Super RC manual 27/06/2011 09:24 Page 4 HI-LINE Super RC 03 Automatic – the desired room temperature is programmed in to the unit and the fan speed is automatically adjusted until the desired room temperature is achieved. l The minimum installation height is 1.8m to the underside of the unit. Fan only – allows user selection of any of the 3 available fan speeds irrespective of room temperature or water temperature in the coil.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 5 04 HI-LINE Super RC 5.0 Preparation Before proceeding with the installation, unpack the carton contents and check against the checklist below: 1. HI-LINE Super RC fan convector. 2. 22mm isolating valves (1 pair). 3. Instruction manual. 4. Warranty card. 5. Fixing kit (rubber mounts and cable gland). 6. Remote control handset. 6.0 Fixing l Using the fixing dimensions below (see fig. 1), mark the fixing hole positions on the wall.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 6 HI-LINE Super RC 05 7.0 Water Connections l Connect unit to system flow and return pipes using the two 22mm isolating valves (see fig. 3 & 4). Dimensions (mm) l Ensure system is flushed in accordance with recognised best practice and a suitable inhibitor is added to the system as necessary. l Open valves fully, check pipe connections for leaks and vent the heat exchanger - see Commissioning Procedure.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 7 06 HI-LINE Super RC 8.0 Electrical Connection WARNING: This appliance must be earthed. The electrical installation must comply with local or national wiring regulations. l This unit is supplied with factory fitted test leads. Remove these and discard. l A fused electrical spur with a maximum 3A fuse and a switch, having 3mm separation on all poles, must be provided in an easily accessible position adjacent to the unit.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 8 HI-LINE Super RC 07 9.0 Commissioning Procedure l Fill and vent the system. l Open both valves fully and check for leaks at pipe connections. l Refit the outer case and secure using the 2 fixing screws. l Check the operation of the unit by following the operating instructions. l When installation and commissioning are complete, hand over instruction manual to end-user. l Switch on electrical supply.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 9 08 HI-LINE Super RC 10.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 10 HI-LINE Super RC 09 11.0 Operating Instructions Description This HI-LINE Super unit is fitted with a control system that provides either automatic or manual control of the unit. In automatic mode the desired temperature set point is selected and the unit will adjust the fan speed according to the difference between the actual room temperature and the set point.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 11 10 HI-LINE Super RC 11.0 Operating Instructions (continued...) Operation Display Manual Power off No Display Manual mode can be used for air circulation without heat or for manual control of the heating function.
23674 HiLine Super RC manual 27/06/2011 09:25 Page 12 HI-LINE Super RC 12.0 Troubleshooting 11 (continued...
23674 HiLine Super RC manual 27/06/2011 09:24 Page 1 MYSON Eastern Avenue, Team Valley, Gateshead, Tyne & Wear NE11 0PG, UK T: 0845 402 3434, F: 0191 491 7568, sales@myson.co.uk, www.myson.co.uk Serial Number Location: Inner chassis position heatingthroughinnovation. After Sales Service: Spare parts and technical help on all Convector products are available from MYSON Service. 01.06.2011 ISSUE 4 MYSON Service, Somerden Road, Hull, East Yorkshire HU9 5PE T: 01482 713927, F: 01482 789056, service.