Specification

Wire Short
Amps Main No. of Max. Catalog Hub 5th Dimensions (in.)
Cover Range Circuit Bypass Ref.
Max. Breaker Spaces Cir. Service Number Type Jaw H W D Type AL/CU Rating Type Fig.
Field Installed Main Breaker
100 MP-T 2 2 OH JC002CS
RX - 18.1 7.0 3.6 Ring #14-1/0 10,000 - 1
125 MP-T 2 2 OH/UG JC002CZ
RX - 14.1 14.1 4.6 Ring #14-1/1 10,000 - 2
125 MP-T 2 2 OH JC002AR
RX - 22.1 7.0 3.6 Ring #14-1/2 10,000 - 3
(1) MD-T, 4 6 OH/UG JC0406L1200H RX ECMC5J 19.7 17.1 5.0 Ring #6-250 kcmil 22,000 - 4
MD-HT
200 or 4 6 OH/UG JC0406L1200RH RX ECMC5J 19.7 17.1 5.0 Ringless #6-250 kcmil 22,000 - 4
(2) MP-T,
MP-HT 4 6 OH/UG JC0406L1200RHJB RX Included 19.7 17.1 5.0 Ringless #6-250 kcmil 22,000 Horn 4
(2) MD-T(R), (1) 600 kcmil
400 MD-HT (R), 2 2 OH/UG JC0404L1400RLM HD S35815-2 29.0 27.0 6.0 Ringless or 22,000 Lever 6
MP-T, MP-HT (2) 250 kcmil
Factory Installed Main Breaker
125 MP2125KH 2 2 OH/UG JC0202B1125RJB RX Included 17.0 16.0 5.0 Ringless #6-250 kcmil 22,000 Horn 5
200 MPD2200KH 2 2 OH/UG JC0202B1200 RX ECMC5J 17.0 16.0 5.0 Ring #6-250 kcmil 22,000 - 5
200 MPD2200KH 2 2 OH/UG JC0202B1200R RX ECMC5J 17.0 16.0 5.0 Ringless #6-250 kcmil 22,000 - 5
200 MPD2200KH 2 2 OH/UG JC0202B1200RJB RX Included 17.0 16.0 5.0 Ringless #6-250 kcmil 22,000 Horn 5
Dimensions shown are representative of outside box length, width, and
depth and do not include allowances for mounting bumps, endwalls,
covers, hubs or hardware protrusions. Dimensions are subject to change.
Not suitable for 5th jaw applications.
Selection and Application Guide
meter
Murray Electrical Products
Siemens Energy & Automation, Inc.
3333 Old Milton Parkway
Alpharetta, GA 30005
www.murrayconnect.com
2005 Siemens Energy & Automation, Inc. All Rights Reserved.
Siemens is a registered trademark of Siemens AG. Murray is a registered trademark of Siemens Energy & Automation, Inc. Product names
mentioned may be trademarks or registered trademarks of their respective companies. Specifications are subject to change without notice.
MYSA-MCSA1-0505 New 4M0505PP Printed in USA
Combination Meter Sockets
Surface Mount Meter Mains, 1 Phase, 3 Wire 120/240V AC
Features
UL listed
Pad locking provisions on all devices
Horn bypass and 5th jaw available as noted
Suitable for use only as service entrance equipment
Contact local utility to confirm meter socket placement
prior to installation
Closure plate included for OH/UG feed devices
Figure 1
100A meter main (field
added), OH feed only
Figure 2
125A meter main (field
added)
Figure 3
125A meter main (field
added), OH feed only
Figure 4
200A meter main (field
added), side hinge door
Figure 6
400A meter main, side
hinge door
Figure 5
125A and 200A meter
main, side hinge door