PV Cable Specifications

P H O N E : ( 8 0 0 ) 3 4 3 2 5 7 9 F A X : ( 8 2 8 ) 3 8 9 3 9 2 2 W W W . A D C A B L E . C O M
PV PHOTOVOLTAIC CABLE
7
Dual Pass 2kV Rated PV
Cross-Linked Polyethylene Insulated PVC Jacketed
18 - 750 MCM • 2000 Volts • 105°C Dry and 90°C Wet
Description
ADC’s Solarlink brand Photovoltaic cable has a chemically cross-
linked polyethylene insulation with a sunlight resistant PVC jacket.
Applications
Appropriate for use in solar power applicatioins that require
2,000 volt rating. For use in grounded interconnection and un
-
grounded Photovoltaic power systems.
Construction
Conductors: Stranded bare copper conductor per ASTM B-3, B-8.
Available in 7 or 19 stranded versions as well as tinned copper.
Insulation: White Chemically Cross-linked polyethylene with
colored sunlight resistant PVC jacket.
Colors: Black, Green, White, Red. Print on one side with a
contrasting ink. An extruded stripe and other colors are available
upon request.
Industry Listings & Standards
UL Listed as Photovoltaic Cable per Standard Subject 4703 and 44
90°C Wet/105°C Dry Rated
Gasoline and Oil Resistant II
RoHS Compliant
Sunlight Resistant
VW-1 Rated
The information contained on this specification is intended to be used a guide in product selection and is believed to be reliable.
ADC has made every effort to ensure the data shown above is accurate at the time of publication. This specification is subject to change anytime without notice. REV0410
3182DPV 18 7 60 30 .226 27.00 5.40
3162DPV 16 7 60 30 .238 32.00 7.97
3142DPV 14 7 60 30 .251 39.00 12.78
3122DPV 12 7 60 30 .270 49.00 20.20
3102DPV 10 7 60 30 .294 65.00 32.05
3082DPV 8 7 70 30 .344 95.00 51.05
3062DPV 6 7 70 30 .381 130.00 80.90
3042DPV 4 7 70 30 .429 188.00 128.90
3032DPV 3 7 70 30 .460 229.00 162.50
3022DPV 2 7 70 30 .489 277.00 204.90
3012DPV 1 19 90 30 .572 360.00 258.00
30102DPV 1/0 19 90 30 .613 437.00 326.00
30202DPV 2/0 19 90 30 .659 535.00 411.00
30302DPV 3/0 19 90 30 .710 655.00 518.00
30402DPV 4/0 19 90 30 .768 806.00 653.00
302502DPV 250 MCM 37 105 30 .845 962.00 772.00
303002DPV 300 MCM 37 105 30 .900 1133.00 926.00
303502DPV 350 MCM 37 105 30 .951 1305.00 1081.00
304002DPV 400 MCM 37 105 30 .998 1475.00 1235.00
305002DPV 500 MCM 37 105 30 1.083 1810.00 1544.00
306002DPV 600 MCM 61 120 30 1.193 2179.00 1853.00
307502DPV 750 MCM 61 120 30 1.298 2676.00 2309.00
Cable Data
Part Number AWG Strand
Insulation
Thickness
(mils)
Jacket
Thickness
(mils)
Nominal O.D.
(inch)
Approximate
Net Weight
lbs/1M’
Copper Weight
per lbs/1M’
Cable Identification
18-16 AWG: “ADVANCED DIGITAL CABLE INC.
XX AWG (UL) PV WIRE 2KV 90C WET OR 105C DRY
SUN RES UV RATED VW-1
DIRECT BURIAL RoHS E324841”
14 AWG-750 MCM: “ADVANCED DIGITAL CABLE
INC. XX AWG (UL) PV WIRE 2KV 90C WET OR 105C
DRY SUN RES UV RATED VW-1 OR RHW-2 DIRECT
BURIAL RoHS E324841”
Bare Copper
XLPE Insulation
PVC Jacket