Household MRV Ceiling Concealed Type Room Air Conditioner AE092FCAHA AE182FCAHA 0010570925 A
1
2
AE092FCAHA AE182FCAHA 3
Part description Remote controller Heating operation indication Dehumidifying operation indication Cooling operation indication Fan only operation indication Automatic operation Operation indicator Power ON/OFF key Clock display Used to turn on /off the machine.
Important Points of Safety The following four important points of safety and suggestions should be paid great attention: ! Warning: Misuse may cause fatal result such as death or serious injury etc. ! Attention: Misuse may cause human injury or damage of machine, in some case fatal results. Content marked with this ìforbiddenî sign should be absolutely forbidden, otherwise may cause damage of machine and human injury of the user.
Important Points of Safety ! Warning Warning for use l Avoid your body being blown directly by cold wind for long period, otherwise your health may be affected. l If something abnormal (e.g.: burnt smell etc.) occurs, stop running the machine, shut down the manual power switch and contact after service. Continuous operation in disorder may cause fire hazard or electric shock etc.
Important Points of Safety Attention Attention points for use * Ensure ventilation of the room* DONíT lay any burning facilities if the machine is used with in place where winds produced by burning facilities. Deficient the machine can reach. Incomplete ventilation can cause oxygen combustion of burning facility may shortage. be caused otherwise. * Check whether installation bench of the machine is * DONíT clean the machine with damaged after a long period water. Electric shock may occur of use.
Operating instructions AUTO, FAN operation 1 Unit start Press the "ON/OFF" key to turn on the unit. TheLCDontheremotecontrollerdisplaystheprevious operatingconditions(excludingprevioustimer,sleepand louver conditions). Theremotecontrolleroperationindicatorturnson. 2 Select operation mode 4 R AM ROOM TEMP MIN HIGH AUTO LOW 1 Pressthe"MODE"keytoaltertheworkingmode.
Operating instructions Recommended operation mode: COOL, DRY, HEAT operation 1 Unit start Pressthe"ON/OFF"keytoturnontheunit. TheLCDontheremotecontrollerdisplaysthepreviousoperatingconditions(excludingprevioustimer, sleep and louver conditions). Theremotecontrolleroperationindicatorturnson. Please use cooling mode in summer and heating mode in winter. Please use DRY mode in spring or autumn humid climate. 2 Select operation mode Pressthe"MODE"keytoaltertheworkingmode.
Operating instructions TIMER ON/OFF function Please adjust the clock before using timer function. You may set the air conditioner automatically turn on or turn off when you wake in the early morning, come off work or after you fall asleep. 1. Set the operation mode after the unit is turned on. R AM TIMER ON 1 ROOM TEMP The operation indicator on the remote controller turns on, and the LCD screen displays the operation mode. AM TIMER MIN HIGH 2.
Operating instructions TIMER ON-OFF operation 1. After unit starts, select your desired operation mode. R TIMER ON ROOMTEMP AM AM LOW DIM HGI AUTO TIMOEFR The operation indicator turns on and the operation mode is displayed on the LCD screen. 1 AM 2. Timer mode selection 3 TIMER 2 SET SWING CLOCK 4 6 TIME SLEEP TEMP FAN SPEED MODE 5 TIMER ON AM 12:00 TIMER ON TIMER OFF 12:00 AM TIMER OFF TIMER ON TIMER OFF BLANK AM 12:00 AM 12:00 TIMER ON-OFF Select TIMER ON-OFF mode.
Operating instructions SLEEP function Using SLEEP function R Before using this function, the time must be checked and set. After the unit starts, set the operation status, then press "SLEEP" key. AM SETTEMP AUTO LOW Before going to bed, you can press the "SLEEP" key on the remote controller and the air conditioner will operate in comfortable SLEEP mode and bring you a sound sleep.
Troubleshooting The following cases are not troubles. Water flow sound is heard. During operation, the air conditioner may sometimes exhibit a sound of "clatter" or "rumble". This is the common sound of refrigerant flow but not a trouble. "Hua-Hua" A sound of "Pi-Pa" is generated. This is caused by the thermal expansion or cold shrinkage of plastics. Smells are given off. Sometimes there are smells in the air flow from the indoor unit.
Troubleshooting In DRY operation, when the room temperature reaches 2* higher than temp. setting,the unit will run at "lOW"fan speed regardless of fan speed setting. During DRY operation, there is no air sent out or fan speed cant be changed. In HEAT mode, the outdoor unit generates water or steam. This occurs during removal of the frost (in defrosting operation) on the radiator of outdoor unit. Defrost operation In HEAT mode, the indoor fan still keeps running even the unit operation stops.
When fault occurs Poor cooling or heating Is the operation controller adjusted as required? Is there any door or window Are there any obstructs before the air inlet or outlet? left open? Poor cooling Is there any other heat source in the room? Is there any direct sunlight into the room? Are there too many people in the room? If, after the above checks and the corresponding corrective actions, the system remains abnormal operation, or the following facts appear, please turn off the air conditioner and t
Notice to users Notice to users l To ensure proper operation of the system, the user shall follow this instruction manual to install the unit. l When handling the air conditioner, please be care not to scratch the case surface. l This instruction manual describes the installation method aided with the installation tools specified by Qingdao Haier Air Conditioner Electronics Com., Ltd.
Installation precautions Before installing, do read this "Safety precautions" carefully to guarantee the proper installation. The below attentive matters are divided into" ! Warning " and " ! Note" two parts. When the wrong installation occur, it is very possible death and severe injury and other serious accidents will happen. For those items are listed in " ! Warning"part. But even the items listed in "! Note" part can also cause serious accidents.
Installation precautions ! Attention This description does not address to all possible cases. For new requirement and query, please consult the regional sales center of Haier Air Conditioner General Co., Ltd. ! Warning This instruction manual must be read carefully before beginning of installation, improper installation may cause accidents and thus bring about machine damage and personal casualty. Installing tools 1. Screw driver 6. Pipe cutter 2. Hacksaw 7. Pipe expander 11. Measuring tape 3.
Installation procedure Electrical requirements l The power supply shall be connected from the outdoor side. (For models with electric-aided heating function, the power supply to the indoor unit shall be connected at the indoor side The power cord size is 3 x (1.25-1.5)mm2, type of YZW). l A separate power circuit shall be supplied and connected by a qualified electrician according to the wiring rules specified in the corresponding national standard. l A current leakage breaker must be installed.
Installation procedure ! Choosing the installation location Caution Please do not install the unit in places where flammable gases may be leaked. In case that gas is leaked and accumulated around the unit, it may cause dangers of fire etc. The indoor unit shall be installed at locations where cold and hot air could evenly circulated. The following locations should be avoided: l Places with rich saline matters (seaside regions).
Installation procedure Installation of indoor unit ! Warning lThe unit shall be installed at locations enough to support the unit. If not, the air conditioner may fall down and cause personal injury. lThe unit shall be installed according to the specifications to resist to strong wind and earthquake. Improper installation may cause dangers of unit falling down etc. After selecting the unit installation location, proceed the following steps: 1.
Installation procedure Installation of indoor unit l When installing the cassette hind type indoor unit, a specially designed return air bellows shall be installed, as shown in Figure 3, Figure 4. l The distance between the air duct outlet and the air conditioner air outlet shall not exceed 0.5 m. Installing building roof *0.
Installation procedure Installation of indoor unit Installing the suspension screw: Use M8 or M10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, M10 size is the only choice). These screws shall be installed as follows with space adapting to air conditioner overall dimensions according to the original building structures. Wooden structure A square wood shall be supported by the beams and then set the suspension screws.
Installation procedure Installation of remote controller Installation of the remote controller 1. Remove the back cover of the remote controller Firstly detach the remote controller back cover at the bottom, then detach at the top. The whole back cover of the remote controller could be removed. AM * * * ** Remote controller bottom Remote controller back cover 2.
Installation procedure Drain pipe ! Caution l In order to drain water normally, the drain pipe shall be processed as specified in the installation manual and shall be thermal insulated to avoid dew generation. Improper hose connection may cause indoor water leakage. Requirements l The indoor drain pipe shall be thermal insulated. l The connection part between the drain pipe and the indoor unit shall be insulated so as to prevent dew generation.
Installation procedure Refrigerant piping ! Caution l In installation, if there is refrigerant gas leakage, please take ventilation measures immediately. The refrigerant gas will generate poisonous gas upon contacting fire. l After installation, please verify that there is no refrigerant leakage. The leaked refrigerant gas will produce poisonous gas when meeting fire source such as heater and furnace etc. Allowable pipe length and drop These parameters differ according to the outdoor unit.
Installation procedure Refrigerant piping Vacuum pumping With a vacuum pump, create vacuum from the stop valve of the outdoor unit. l Emptying with refrigerant sealed in the outdoor unit is absolutely forbidden. Open all valves Open all the valves on the outdoor unit. Gas leakage detection Check with a leakage detector or soap water that if there is gas leakage at the pipe connections and bonnets.
Installation procedure CElectric wiring ! Warning l The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire. ! l During wiring connection, the power cord shall be of the specified cable and reliably fastened so that external forces applied to the cable wouldnt transfer to the terminals.
Installation procedure Electric wiring Wiring connection method : (the wiring diagram is attached inside the machine) 1) Ring terminal connection method If there is a ring at the end of the connection wire, the wire connection method is as shown in the right figure. Remove the terminal screw and insert it through the ring at the connection wire end, then connect to the terminal board and fasten the screw.
Installation procedure Field setting Field setting Field setting the unit number In order to realize central control of the MRV air conditioning system, its necessary to set the indoor unit number (control address). Indoor unit number setting Indoor unit number setting switch and confirmation of the settings. There is a 4-position dial switch for setting the indoor unit number on the computer board of the indoor unit.
List of troubles List of displayed troubles on the remote controller Trouble description Displayed code Ambient temperature sensor fault E1 Indoor unit gas pipe temperature sensor abnormal E2 Indoor unit and outdoor unit signal transmission abnormal E3 Faulty communication between indoor unit 846 chip and 808 chip E5 Indoor unit liquid pipe temperature sensor trouble E6 Indoor unit and remote controller communication abnormal E7 Trouble with outdoor unit E9 List of indicated troubles with ou
Installation check and trial operation Check if the drain pipe and connection wires are arranged properly. The drain pipe shall be put below. The connection wire shall be put above. Be sure to wrap the drain pipe (especially the indoor part and the part inside the machine) with thermal insulating materials. The drain pipe shall be made into slope. Avoid bulging up or down or phenomena shown right figure in the run.