LINEAR STEAMHEAD INSTALLATION
NOTE: Steamhead to be installed 6-12” above the finished floor. Refer to the
Mr. Steam Installation Manual for additional installation information.
• Do not locate the steam head in any location where the steam
emission zone is near a seat, bench, or any space occupied by any
persons. (See Fig.1) for a diagram of the steam emission zone.
• Determine the location of the nished wall surface. Mount the steam
head between two studs using the four slotted holes to position the
steam head face to be ush or extend 1/8” from the nished wall
surface.
• Use a level to ensure the steam head is level in both the horizontal
and vertical positions (see Fig.2) and the steam head face is ush or
extend 1/8” from the nished wall surface. Install the four screws in the
mounting holes to secure the steamhead.
• After the nished wall surface has been installed use high
temperature caulking around the steam outlet as required to
make a water proof seal. (see Fig.3)
Copper Tubing
or Brass Pipe
(not provided)
Steam Outlet
Threaded
Adaptor or
Thread Plug
as required
(not provided)
14
1
/
8
” – 14
1
/
2
”
Level
Steam
head
6”-12”
above
floor
STEAM
EMISSION
ZONE
Steam Room
Interior
STEAM
EMISSION
Cement Board
Thin Set
Finished Wall
Surface
Flush to
1
/
8
”
STUD
Steam Outlet Face
Silicone
Silicone
Figure 1
Figure 2
Figure 3
LINEAR STEAMHEAD INSTALLATION
For Illustrative purposes only. Consult with qualified designer,
architect or contractor for steamroom construction details.
IMPORTANT The information in this guideline is designed to provide a general overview of how MrSteam products are installed. The diagrams are for Illustrative purposes only. NEVER use this document for the Installation,
Operation or Maintenance of any MrSteam product. For Installation, Operation and Maintenance information, only use the specic Installation, Operation and Maintenance manual supplied with each Mr. Steam product. The
specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product contains important information required for the safe and reliable installation and operation of the product. Failure to use
the specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product may result in product damage, property damage, death or personal injury. If you do not have an Installation, Operation
and Maintenance manual please contact MrSteam for a free copy, or download a copy from www.mrsteam.com. If you have any questions about the installation, operation or maintenance of any MrSteam product please
contact a customer or technical service representative using the contact information on the back cover of this guideline.