Owner Manual

18
REMOTE TEMPERTURE PROBE
INSTALLING A REMOTE TEMPERATURE PROBE
1. The Probe must be installed:
a. On a vertical surface
b. 4-5 feet above the Floor
Locate the Probe in a location representative of the desired
steambathing temperatures. Do not locate the probe above or
near the steam head or direct steam emissions. The probe has
an integral 20 ft. cable. Ensure that the probe and iSteam
control are located accordingly.
2. Drill a 1/4 inch hole in the wall. Do not oversize or undersize
the hole. Clean area thoroughly.
3. Route the end of the temperature probe cable with the
temperature probe through the wall into the steam room
as shown in Diagram 1.
IMPORTANT NOTE: Do not strain, staple, pinch or otherwise
damage the probe cable.
4. With a minimal length of the cable exposed apply silicone
(provided) to the hole in the wall as required to create a
moisture seal as shown in Diagram 2.
5. Push the Remote Temperature Probe into hole as required to
leave between 1/4”- 1/2” of the probe. Exposed as shown
in Diagram 3
6. Insure a minimum of 1/4” of the probe is exposed to the air.
Failure to do so may result in an inoperative control and a
hazardous condition.The exposed area of the probe must
be free of silicone or any materials that prevent direct exposure
to the steam room air. Failure to do so may interfere with the
ability to sense temperature and may result in excessive steam
room temperatures
The Remote Temperature Probe is required when a steam control is installed outside the steam
room.
Diagram 1
Diagram 2
Diagram 3
IMPORTANT The information in this guideline is designed to provide a general overview of how MrSteam products are installed. The diagrams are for Illustrative purposes only. NEVER use this document for the Installation,
Operation or Maintenance of any MrSteam product. For Installation, Operation and Maintenance information, only use the specic Installation, Operation and Maintenance manual supplied with each Mr. Steam product. The
specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product contains important information required for the safe and reliable installation and operation of the product. Failure to use
the specic Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product may result in product damage, property damage, death or personal injury. If you do not have an Installation, Operation
and Maintenance manual please contact MrSteam for a free copy, or download a copy from www.mrsteam.com. If you have any questions about the installation, operation or maintenance of any MrSteam product please
contact a customer or technical service representative using the contact information on the back cover of this guideline.