NEVER use this document for the Installation, Operation or Maintenance of any MrSteam product. For Installation, Operation and Maintenance information, only use the specific Installation, Operation and Maintenance manual supplied with each Mr. Steam product. The specific Installation, Operation and Maintenance manual that is supplied with each Mr. Steam product contains important information required for the safe and reliable installation and operation of the product.
GENERATOR LOCATION LOCATING THE MR.STEAM® GENERATOR Select a location as near as practical to the steam room. Typical locations include: closet, vanity cabinet, climate controlled attic or basement. For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. 1. Locate steambath generator within 60 feet of steam room. Note: The standard length of the cable for connecting the control to the steam generator is 30 feet.
POWER CONNECTION FIELD POWER SUPPLY CONNECTION Main Electrical Disconnect Panel 240v Powerline For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. Please refer to the wiring diagram in the Mr.Steam Installation Manual for complete wiring information.
WATER FEED WATER FEED Water Feed Line (3/8” NPT) For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. 1. Connect cold water line. 2. Provide a shut off valve, and a copper or brass union on the water supply line, upstream of the steambath generator 3. Do not overheat inlet solenoid valve with solder connections. Overheating will damage parts. 4. Flush inlet water line thoroughly before making connection to unit. 5.
Steam Outlet Pipe STEAM OUTLET STEAM OUTLET PIPE For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. Steam Outlet (1/2” NPT) 1. Please provide a 1/2” copper or brass union on steam line. 2. Use 1/2”- brass pipe or rigid copper tubing from unit to steam head as permitted by codes. 3. Insulate steam line using pipe insulation rated 250˚ F or higher (for example Fiberglass). 4.
DRAIN LINE MANUAL DRAIN LINE Drain ( 1/2” NPT) NOTE: A drain valve is provided to facilitate servicing. Provide a drain line connection from steambath generator drain valve according to National and local Codes. Check local plumbing code for receptor, trap and vent requirements. Unit drains by gravity. 1/2” copper or brass union needed. Manual Drain Valve (shown in open position) Pitch as required for gravity drain For Illustrative purposes only.
AUTOFLUSH OPTIONAL AUTOFLUSH OPERATION The optional AutoFlush System feature automatically drains the Mr.Steam® system following each use. A time delay allows the water to cool down (about two hours) before it drains by gravity for a safe and gentle operation. NOTE: If the Express Steam option has been installed, the AutoFlush will drain for ten minutes then refill with fresh water to begin the pre-heat cycle.
CONDENSATION PAN CONDENSATION PAN PN 103867 CONDENSATION PAN 3/4” Outlet For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. 8 IMPORTANT The information in this guideline is designed to provide a general overview of how MrSteam products are installed. The diagrams are for Illustrative purposes only. NEVER use this document for the Installation, Operation or Maintenance of any MrSteam product.
(Optional) (only available factory installed) Suitable for all MS and SUPER Models. Express steam is equipped with a low power heating element and thermostat to keep the water in the tank warm enough to bring up steam quicker. All express steam components and wiring are installed at the factory. No additional wiring or plumbing is required by installers.
MS GENERATOR TYPICAL MS GENERATOR Contactor Liquid Level Control Board Water Feed Solenoid Liquid Level Probe Water Inlet Plug & Play Connection Safety Valve Access Cover Steam Outlet Express Steam Heater (optional) Heating Element Drain Valve Stainless Steel Tank 10 IMPORTANT The information in this guideline is designed to provide a general overview of how MrSteam products are installed. The diagrams are for Illustrative purposes only.
(MS Super 4E, 5E & 6E) Standard Tandem Cable for Connecting (2) Units PN 103904 Secondary Unit • Optional Tandem Cable for Connections up to (5) Units PN 103917 TANDOM INSTALLATION TANDEM STEAM GENERATOR INSTALLATION Primary Unit (unit control connected to Primary Unit) Refer to the Mr.Steam Installation manual for additional installation information. For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details.
STEAM CONTROL LOCATION LOCATING THE ISTEAM®, ITEMPO®, ITEMPO/PLUS®, & AIR TEMPO CONTROLS Run cable through conduit inside wall cavity. Cable not necessary with AirTempo. For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. Locate control where it will sense general room temperature and NOT direct steam emission from the steam head.
STEP 1 PLUG the 30’ control cable into the iSteam3 control pigtail (1a). Turn the generator on and test the control to verify correct connection. With proper function, proceed to Step 2. CAUTION Do not force or twist cable ends together. Forcing or twisting cable ends may damage the connectors. Control Cable 97 1a IMPORTANT: Turn power to the steam generator OFF before installing the control. Failure to turn the power off will result in an inoperable control.
AIRTEMPO CONTROL SURFACE MOUNT AIRTEMPO SURFACE MOUNT INSTALLATION Step 1 Determine the desired installation location of the control. The AirTempo controls are designed to be installed inside or outside the steam room as a matter of personal preference. If the control is installed outside the steam room a Remote Temperature Probe part number MSTS must be installed inside the steam room. See Remote Temperature Sensor (page 17). Step 2 • Remove the surface mount bayonet from the back of the AirTempo Control.
Step 1 • Remove the surface mount bayonet from the back of the AirTempo control. The surface mount bayonet is not used when flush mounting. Step 2: Remove outside ring from AirTempo control. NOTE: Be careful not to drop controller when ring pops off Step 3 • Using the template provided, cut the hole in the desired location. Do not oversize or undersize the cutout. Ensure the template is level before cutting the hole. • Test fit the flush mount box to ensure the hole is the corre size.
ITEMPO INSTALLATION ITEMPO® OR ITEMPO/PLUS® CONTROL INSTALLATION IMPORTANT: Turn power to the steam generator OFF before installing the control. Failure to turn the power off will result in an inoperable control. 1. Firmly connect the control cable to the control. Turn on power to the steam generator and test the control to verify correct connections. Test per instructions. Proceed with installation and verification of proper control function. 2. Remove & discard peel-off paper to expose adhesive liner.
Locating Controls Outside the Steam Room by Using Remote Temperature Sensor For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. REMOTE TEMPERATURE SENSOR REMOTE TEMPERATURE SENSOR MSTS Remote Temperature Sensor Locate the RemoteTemperature Sensor (MSTS) where it will sense general room temperature and NOT direct steam emission from the steam head. Refer to the Mr.
REMOTE TEMPERTURE PROBE INSTALLING A REMOTE TEMPERATURE PROBE The Remote Temperature Probe is required when a steam control is installed outside the steam room. 1. The Probe must be installed: a. On a vertical surface b. 4-5 feet above the Floor Locate the Probe in a location representative of the desired steambathing temperatures. Do not locate the probe above or near the steam head or direct steam emissions. The probe has an integral 20 ft. cable.
Route the control cable (provided with the control) from the wall cutout to the steam generator. IMPORTANT: Do not strain, staple, pinch or otherwise damage the control cable. Route cable as required to permit replacement. The 30’ (and optional 60’) control cable features identical Mini-Din connectors at both ends. Note: The standard length of the cable for connecting the control to the steam generator is 30 feet. The steam generator and control must be located accordingly. A 30 foot cable is standard.
AROMASTEAM3 SYSTEM AROMASTEAM SYSTEM For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. Electronic Oil delivery system evenly infuses aroma into steam for an aromatherapy experience. Complete with in-shower control, oil container caddy, hoses, fittings and oil atomizer. AromaSteam Essential oils are available in one-liter bottles. Not for use with acrylic or fiberglass rooms.
Step 1 Attach Locating Nipple to steam line. Step 2 Provide a 1 1/2” hole in finished wall to mount the steamhead. For Illustrative purposes only. Consult with qualified designer, architect or contractor for steamroom construction details. Oil Well Step 3 Remove Locating Nipple and attach steam head, with nipple sized for the finished wall thickness. NOTE: Steamhead to be installed 6-12” above the finished floor. A 1.5” diameter hole in the steam room is required to mount the steamhead.
LINEAR STEAMHEAD INSTALLATION LINEAR STEAMHEAD INSTALLATION Figure 1 NOTE: Steamhead to be installed 6-12” above the finished floor. Refer to the Mr. Steam Installation Manual for additional installation information. STEAM EMISSION • Do not locate the steam head in any location where the steam emission zone is near a seat, bench, or any space occupied by any persons. (See Fig.1) for a diagram of the steam emission zone.
Enjoy essential oils by placing a drop or two, into your steamhead as shown in the illustration. CAUTION: Use essential oils with caution. Essential oils are for external use only. Keep out of reach of children. Essential oils are highly concentrated and are potent substances and should not be applied directly to the skin as they can be irritants. Use essential oils with caution. CAUTION: Place the drops into the Mr.Steam AromaSteam steamhead well prior to turning on the steambath.
CHROMASTEAM3 INSTALLATION CHROMASTEAM3 INSTALLATION Step 1. Locating the control box. Determine the desired location of the ChromaSteam3 control box outside the steam room in a dry location. (Fig.1)Step 2. Installing the control box. Using screws and washers, affix the control box to a stable vertical ChromaSteam3 Controller surface (e.g., stud) using the mounting holes on either side of the control box (Figure Figure 1 2).Step 3. Install junction box.
1. Determine the placement of the light. Do not install the fixture assembly (light) where direct contact with steam or water emission could occur. Do not install the light in a location where it could become submerged. Light Fixture LED Cluster 2 . The light requires a 41⁄4”diameter hole for mounting. 3. Provide electrical service (120VAC) with flexible cable only. Pass cable through ceiling opening and wire fixture in accordance with NEC and local electrical code.
AUDIOSTEAM3 INSTALLATION AUDIOSTEAM3 INSTALLATION Step 1. Locating and Installing AudioSteam (Figure 1A) To prevent water from getting inside the device, AudioSteam should be mounted on two stable vertical surfaces (e.g., studs) as shown in (Figure 1B). Using screws and washers, firmly attach AudioSteam using the upper mounting holes, one at a time, on each side of the unit. Repeat the process for the lower Connect a 1/8” (3.5 mm) stereo audio cord mounting holes (Figure 1B).
MS-Speakers • Two flush-mount two-way speakers for steam/shower use, polypropylene cones, ABS frames with grills. • Suitable for almost any source of audio input. • Rated 60W peak power 8 ohms impedance with 1” tweeter for full range sound. • Use only CL2 or CL3 UL listed wires to connect speakers to audio source. • Available in Round (5 1/2 inch) and Square (7 inch) in both white and black designs.
(figure 1) 171/32” Right Bracket Min.1/2” Thick Cement Board (with hole hinge pin on the left side) Min. 1/4” Thick Tile Max. 11/8” Thick Wall Screws Left Bracket (with hole hinge pin on the right side) (figure 2) (figure 3) 147/8” Insert seat assembly to brackets. Place seat with the MrSteam logo and fasteners on the bottom. Insert hinge pins to both left and right brackets while the seat assembly is in vertical position. Securely tighten both hinge pins, using Allen wrench provided.
Connecting SteamLinx A to the Steam Generator Step 1. Disconnect power to the generator at the breaker box (figure 1). Step2. Locate the SteamLinx Module (figure 2). Step3. On Steam Generator- remove knock-out. Remove generator cover. Route the SteamLinx A cable through the knockout. (figure 3). Locate the circuit board (figure 4). Plug the SteamLinx A into the white connector located at the far left side of the circuit board. Replace cover and screws. Restore power.
MRSTEAM® A leader and innovator in steam shower systems, spa products and experiences for residential and commercial use. MrSteam offers the highest quality products, affordable pricing, top class warranties and unmatched customer service. CONTACT US Headquarters Sussman-Automatic Corporation 43-20 34th Street Long Island City, NY. 11101 USA tel 1-800-76 STEAM (767-8326) ® West Coast Sussman-Automatic Corporation 9410 South La Cienega Blvd Los Angeles, CA.