iTempo Installation Manual
mr
.
steam
®
Installation & Operating Instructions
______________________________________________________________
6
DIAGRAM 2
Installation Instructions for Round & Square
iTempo
™
and iTempoPlus
™
STEP 1
Determine the desired installation location of the control.
The iTempo
™
and iTempoPlus
™
controls are designed to be
installed inside or outside the steam room as a matter of personal
preference. If the control is installed outside the steam room a
Remote Temperature Probe part number MSTS must be
installed inside the steam room. If the control is installed
inside the steam room the control must be located:
• 4-5 feet above the oor near the bather seating area.
• The control features an integral temperature sensor. Locate
the control in a location representative of the desired steam
bathing temperatures. Do not locate the control above or
near the steam head or direct steam emissions. Locating the
controls near the steamhead or near direct steam emissions
may result in poor steam room temperature control.
• On a vertical wall
• The control cable length is 30 feet. Insure that the control and/or steam
generator are located accordingly. Contact a Mr.Steam technical service
representative if a longer cable is required (60 ft. cable, PN 103990-60).
IMPORTANT NOTE:
The control cable should be run in a dedicated
1” conduit to facilitate installation and service.
IMPORTANT NOTE:
See installation instructions for the MSTS
Temperature Probe before rough-in or installation of control (pgs. 8-9).
STEP 2
Diagram 1
Make a 2-
5
⁄8” wide by 3-
7
⁄8” high cutout in the desired control location.
Do not oversize or under size the cutout.
STEP 3
Diagram 2
Route the control cable (provided with the control) from the wall cutout
to the steam generator. Connect one end of the cable to the steam
generator connector.
Drawings for Illustrative Purposes Only.
2-
5
⁄ 8”
3-
7
⁄ 8”
DIAGRAM 1