M RFS4010 Series RF Switch Installation Guide
MOTOROLA and the Stylized M Logo are registered in the US Patent & Trademark Office. Symbol is a registered trademark of Symbol Technologies, Inc. All other product or service names are the property of their respective owners. © Motorola, Inc. 2010. All rights reserved.
Contents 1.0 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 2.0 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 3.0 LED Codes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 4.0 Hardware Setup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 5.0 Regulatory Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 6.
Introduction 1 Introduction The Motorola RFS4010 RF Switch is a member of Motorola’s RFS Series Wireless Switch family. The RFS4010 RF Switch provides centralized Wireless LAN (WLAN) configuration and management by coalescing a network “intelligence” previously spread across physically distributed access points. The RFS4010 simplifies deployment of a Wired/Wireless 802.11 a/b/g/n network, for a SME/SMB.
2 RFS4010 RF Switch: Installation Guide WARNING! Indicates a condition or procedure that could result in personal injury or equipment damage. 1.3 Warnings • • • • • • • • • • • • • Read all installation instructions and site survey reports, and verify correct equipment installation before connecting the system to its power source. Remove jewelry and watches before installing this equipment. Install the equipment in a rack or on a desktop with adequate dimensions and weight allowances.
Specifications 2 Specifications 2.1 Physical Specifications Width 304.8mm (12.0in) Height 44.45mm (1.75 in) 1 RU Depth 254mm (10.0 in) Weight 2.15 Kg (4.75 lbs) Operating Temperature Operating Humidity Operating Altitude 0°C - 40°C (32°F - 104°F) 5% - 85% RH, non-condensing 10,000 ft @ 28deg C < 15% Relative Humidity 2.2 Power Cord Specifications A power supply is included, however a power cord is not supplied with the switch.
4 RFS4010 RF Switch: Installation Guide 3 LED Codes The RFS4010 RF Switch has four vertically-stacked LEDs on its front panel. Each of the six Gigabit Ethernet Ports have two status LEDs. These LEDs display two colors (green & amber), and three lit states (solid, blinking, and off). The following tables decode the combinations of LED colors and states for the System Status LEDs and the Gigabit Ethernet LEDs. 3.
LED Codes 3.1.
6 RFS4010 RF Switch: Installation Guide 3.1.
LED Codes 3.1.4 Fan LED Fan LED Event Off System Off / POST Start Green Blinking POST in Process Green Solid All System Fans Normal Operation Amber Solid Redundant Cooling Failure System Operational Amber Blinking System Cooling Failure System will be held in reset until the issue is resolved 3.1.
8 RFS4010 RF Switch: Installation Guide 3.
LED Codes 3.2.1 RJ-45 Port Speed LED Port Speed LED Event Off 10 Mbps Green Solid 100 Mbps Green Blinking 1000 Mbps Amber Blinking Port Fault 3.2.2 RJ-45 Port Activity LED Port Status LED Event Off No Link or Administratively shut down Green Solid Link present Green Blinking Activity: Transmit and Receive Amber Blinking Link Fault 3.2.
10 RFS4010 RF Switch: Installation Guide 3.3 SFP Gigabit Ethernet LEDs UPLINK SFP Port speed Port activity 3.3.1 SFP Port Speed LED Port Speed LED Event Green Blinking 1000 Mbps Amber Blinking Module or Tx/Rx Fault Loss 3.3.
Hardware Setup 4 Hardware Setup Console LAN/PoE+ enabled gigabit ethernet UPLINK/ WAN ports 1,2,3,4,5 USB ExpressCard Slot 4.1 Cabling Information UPLINK Console connector ExpressCard Slot USB port Gigabit Ethernet RJ-45 connectors with per-port LEDs and PoE+ The RFS4010 RF Switch has five RJ-45 Gigabit Ethernet ports, one Gigabit SFP (fiber) port, one USB port, one Console connector and one ExpressCard slot. The above diagram shows each of those ports and the cables or devices attached to them.
12 RFS4010 RF Switch: Installation Guide 4.2 Gigabit Ethernet on the RFS4010 RF Switch The RFS4010 RF Switch has five RJ-45 Gigabit Ethernet ports and one 1 combo Gigabit (RJ45 + SFP) uplink port. Using the RJ-45 ports requires connecting a Category-6 Ethernet cable to the port. To use the Gigabit SFP port, first install the SFP Module (Motorola Part Number: Fiber-3000-1S-WWR). 4.2.1 Installing Gigabit Ethernet SFPs 1. Open the bail on the transceiver. Open bail to insert or remove SFP transceiver 2.
Hardware Setup 3. Once the SFP transceivers are properly seated in their ports, close the bails to lock the transceivers in place.
14 RFS4010 RF Switch: Installation Guide 4. Insert the fiber optic cables into the installed transceivers.
Hardware Setup 4.3 Connecting USB Devices USB port The RFS4010 RF Switch contains one USB port for connecting USB flash storage devices to the switch. The switch can use the USB flash storage device for file transfers and firmware updates. Follow the setup instructions below to connect the devices to the switch and then access those devices through the Web UI or Command Line Interface. 1. Connect the USB flash drive to the USB . 2. Wait a few seconds for the drive to be recognized by the switch. 3.
16 RFS4010 RF Switch: Installation Guide 4.4 Rack Mount Instructions To install the RFS4010 RF Switch in a rack: 1. Attach the switch to the 1U rack mount kit using the guides provided. Switch Guides Power Supply Guide Cable Management Back Front Attach to Rack 1U Rack Mount Kit 2. Place the power supply unit in the rack mount tray in the space provided. 3. Attach the mounting tray to the rack using screws appropriate for your rack’s mounting holes.
Hardware Setup 4.5 RFS4010 RF Switch Console Port Setup To add the RFS4010 RF Switch to the network and prepare it for initial configuration: 1. Using the supplied console cable (pictured below), connect the RFS4010 RF Switch serial port to an RS-232 (DB-9) serial port on a separate computer (the “configuration computer”).
18 RFS4010 RF Switch: Installation Guide 2. On the configuration computer, configure a terminal emulation application (such as HyperTerminal) as follows: Terminal Type Port Terminal Settings VT-100 COM port 19200bps transfer rate 8 data bits no parity 1 stop bit no flow control no hardware compression 4.6 Supplying Power to the RFS4010 RF Switch Power Inlet 1. Plug the power supply (Motorola Part Number: 50-14000-244R) into the power inlet at the back of the RFS4010 RF Switch. 2.
Hardware Setup . WARNING! An improper shutdown can render the RFS4010 RF Switch inoperable such that it could require service by Motorola Support. Do not remove AC power without first following the shutdown procedure. An abrupt loss of power can corrupt the information stored on the device. 4.7 Using the RFS4010 RF Switch Reset Button Reset Button The RFS4010 RF Switch has a reset button on the rear of the switch near the power connector. To reset the switch to factory defaults: 1.
20 RFS4010 RF Switch: Installation Guide 3. As soon as the switch resets, depress the reset button on the rear of the switch and continue to hold it through the boot up process until the following message is displayed in the console: Startup config will be RESET to factory default loading linux image 2 ....................... Welcome to RFS4000 CAUTION ! Using the switch reset button will reset all configuration information and settings on the switch to factory defaults.
Regulatory Information 5 Regulatory Information This regulatory section applies to the RFS-4010. For more information refer to section 6, Part Numbers, Support, and Sales. All Motorola devices are designed to be compliant with rules and regulations in locations they are sold and will be labeled as required. Local langauge translations are available at the following website: http://support.symbol.
22 RFS4010 RF Switch: Installation Guide Class 1 Laser devices are not considered to be hazardous when used for their intended purpose. The following statement is required to comply with US and international regulations: CAUTION ! Use of controls, adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure. Radio Frequency Interference Requirements - FCC Symbol Technologies Inc.
Regulatory Information Statement of Compliance Motorola hereby declares that this device is in compliance with all the applicable Directives, 2004/108/EC, 2006/95/EC. A Declaration of Conformity may be obtained from http://www2.symbol.
24 RFS4010 RF Switch: Installation Guide Waste Electrical and Electronic Equipment (WEEE) English: For EU Customers: All products at the end of their life must be returned to Symbol for recycling. For information on how to return product, please go to: http://www.symbol.com/environmental_compliance. Dansk: Til kunder i EU: Alle produkter skal returneres til Symbol til recirkulering, når de er udtjent. Læs oplysningerne om returnering af produkter på: http://www.symbol.com/ environmental_compliance.
Regulatory Information Italiano: per i clienti dell'UE: tutti i prodotti che sono giunti al termine del rispettivo ciclo di vita devono essere restituiti a Symbol al fine di consentirne il riciclaggio. Per informazioni sulle modalità di restituzione, visitare il seguente sito Web: http://www.symbol.com/ environmental_compliance. Magyar: Az EU-ban vásárlóknak: Minden tönkrement terméket a Symbol vállalathoz kell eljuttatni újrahasznosítás céljából.
26 RFS4010 RF Switch: Installation Guide 6 Part Numbers, Support, and Sales Part Numbers Description Part Number RFS4010 with Internal POE and Power Supply RFS-4010-00010-WR Rack Mount Kit RFS-4010-MTKT1U-WR Power Supply Unit 50-14000-244R Motorola’s Enterprise Mobility Support Center If you have a problem with your equipment, contact Enterprise Mobility support for your region. Contact information is available by visiting http://www.motorola.
Motorola, Inc. End-User License Agreement 7 Motorola, Inc. End-User License Agreement BY DOWNLOADING, INSTALLING, OR USING THE SOFTWARE DESCRIBED IN THIS DOCUMENT, YOU OR THE ENTITY OR COMPANY THAT YOU REPRESENT ("LICENSEE") ARE UNCONDITIONALLY CONSENTING TO BE BOUND BY AND ARE BECOMING A PARTY TO THIS LICENSE AGREEMENT ("AGREEMENT"). LICENSEE'S USE OR CONTINUED USE OF THE DOWNLOADED OR INSTALLED MATERIALS SHALL ALSO CONSTITUTE ASSENT TO THE TERMS OF THIS AGREEMENT.
28 RFS4010 RF Switch: Installation Guide interrupt, destroy or limit the functionality of any computer software or hardware or telecommunications equipment. Licensee, not Licensor, remains solely responsible for all Content that Licensee uploads, posts, e-mails, transmits, or otherwise disseminates using, or in connection with, the Software. 4 FEES; SUPPORT AND UPGRADES. Licensor may, at Licensor's sole option, provide support services related to the Software ("Support Services").
Motorola, Inc. End-User License Agreement 9 INDEMNITY. Licensee agrees that Licensor shall have no liability whatsoever for any use Licensee makes of the Software. Licensee shall indemnify and hold harmless Licensor from any claims, damages, liabilities, costs and fees (including reasonable attorney fees) arising from Licensee's use of the Software as well as from Licensee's failure to comply with any term of this Agreement. 10 FAULT TOLERANCE.
30 RFS4010 RF Switch: Installation Guide 8 RFS4010 China ROHS Compliance 有毒有害物质或元素 部件名称 (Parts) 金属部件 (Metal Parts) 电路模块 (Circuit Modules) 电缆及电缆组件 (Cables and Cable Assemblies) 塑料和聚合物部件 (Plastic and Polymeric Parts) 光学和光学组件 (Optics and Optical Components) 电池 (Batteries) 六价铬 (Cr6+) 15 多溴二苯 醚 (PBDE) O 铅 (Pb) 汞 (Hg) 镉 (Cd) O O O O 多溴联 苯 (PBB) O X O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O:表示该有毒有害物质在该部件所有均质材料中的含量均在 SJ/T11363-2006 标准规定的 限量要求以下。 X:表示该有
MOTOROLA INC. 1303 E. ALGONQUIN ROAD SCHAUMBURG, IL 60196 http://www.motorola.