Install Instructions

Release 10.5 Release Notes and User Guide Supplement
FCC Draft, November 2010 Page 11
4 Features
Release 10.5 adds the features listed in Table 1.
Table 1: Release 10.5 Features
Regions
Affected
Products
Affected
Feature
Description
See for
Details
US
All 5.4-GHz
5.4-GHz PMP 100
(FSK)
5.4-GHz PTP 100
(FSK)
5.4-GHz PMP 430
(OFDM)
5.4-GHz PMP 400
(OFDM)
5.4-GHz PTP 200
(OFDM)
Operation to avoid
interference with
Terminal Doppler
Weather Radar
(TDWR)
To avoid interference with TDWR (47
locations, near major airports), 5.4-GHz
US radios must
be professionally installed
have a transmit frequency set on
the AP/BHM at least 30 MHz
(center-to-center) from any TDWR
within 35 km (21.75 mi) of the
AP/BHM or any of its SMs/BHS.
http://www.spectrumbridge.com/udia/se
arch.aspx supports the necessary map
analysis and includes a database for
registering the location of these radios
to expedite interference resolution.
Section 4.1
US
US 5.4-GHz PMP
430 (OFDM)
US FCC Certification
of new product
US 5.4-GHz PMP 430 APs and SMs
are now approved for sale in the US.
As certified, the US 5.4-GHz PMP 430
AP is limited to operate at
no higher than 85% Data
Downlink %
10-MHz and 20-MHz channel
sizes, but not 5-MHz
Lens and reflector were not included in
the certification.
Section 7.6,
Table 10
Section
10.2.1,
Table 11
US
US P11 Hardware
Series 5.4-GHz
PMP 100 (FSK)
US P11 Hardware
Series 5.4-GHz
PTP 100 (FSK)
US FCC Certfication
of new hardware
series
US P11 5.4-GHz PMP 100 APs and
SMs and PTP 100 BHs are now
approved for sale in the US.
As certified, the US P11 PMP 100 AP
and PTP 100 BHM is limited to operate
at
no higher than 75% Data
Downlink %
(Older hardware series are not limited
by Release 10.5.)
Section 7.5,
Table 8,
Table 9
Section
10.2.1,
Table 11
Canada
5.4-GHz PMP 430
(OFDM)
IC Certification of
new product
5.4-GHz PMP 430 APs and SMs are
now approved for sale in Canada.
As certified, the AP is limited to
10-MHz and 20-MHz channel
sizes, but not 5-MHz
For compliant operation, the Region
Code must be set to Canada by the
professional installer.
Section
10.2.2 and