User's Manual

68P8100XYXX-O APRIL 2003 3-23
PRELIMINARY
Internal Review (First Draft - 50% to 60% Complete)
SIMULCAST CONFIGURATION ILLEGAL CARRIER DETERMINATION AND BASE RADIO MEASUREMENT
CHECKING THE TRANSMITTER BIT ERROR RATE
Perform Procedure 3-6 to check the bit error rate (BER) on the transmitter.
NOTE
If the service monitor is already connected, go to step 6.
14 Disconnect the service monitor from the base radio and reconnect the transmit
antenna to the transmit input connector.
15 Turn on the base radio being checked using the On and Off switch on the front of
the power supply module and allow the station to fully initialize.
16 Click the Change to Normal Mode button to return the base radio to normal
operations.
P
ROCEDURE 3-6 HOW TO CHECK THE TRANSMITTER BIT ERROR RATE
1 Turn off the STR 3000 Simulcast Base Radio using the On and Off switch on the
front of the power supply module.
CAUTION
Make sure power to the base radio is OFF. Connecting or
disconnecting RF cables while the transmitter is keyed
could cause personal injury or equipment damage from RF
arcing.
NOTE
If two STR 3000 Simulcast Base Radio rack transmitters are
combined together, turn off all of the base radios in both racks.
2 Disconnect the transmit cable from the base radio.
3 Connect the transmit port to the service monitor.
4 Set the service monitor to monitor the transmit frequency of the base radio being
tested.
5 Turn on the base radio being checked using the On and Off switch on the front of
the power supply module and allow the station to fully initialize.
6 Use the CSS application to read the configuration from the base radio.
See “Reading the Configuration File from a Device” in the STR 3000 Simulcast
Base Radio online help.
P
ROCEDURE 3-5 HOW TO CHECK THE TRANSMITTER FREQUENCY (CONTINUED)
Exhibit 9E