User's Manual

Simulcast Hardware Installation Operating Specifications for the Transmitter
Table 5-12 Operating Specifications for the Base Radio
Specification
Value or Range
Dimensions Height: 22.2 cm (8.75 in.) (5 RU)
Width: 48.3 cm (19 in.)
Depth: 41.9 cm (16.5 in.)
Weight 33 kg (73 lb)
Operating Temperature Range 0 to 50˚ C(32to+122˚ F)
Power Requirements -48 VDC (41-60 VDC)
Power Dissipation 530 W (typical)
640 W (maximum)
Heat Dissipation 2,160 Btu maximum for 1 base radio 12,240 Btu
maximum for 6 base radios
See Table 5-17 for average heat dissipation for each base
radio.
Rack Spacing Designed for mounting in an EIA/TIA standard 19-in.
(48.26 cm) rack
Minimum of 15.24 cm (6 in.) between the cabinet
and the wall
With doors, minimum of 53.34 cm (21 in.) is required
to open the back door.
Because of weight considerations, the
installation should allow access to the rear
of the unit.
O
perating Specifications for the Transmitter
Table 5-13 lists the operating specifications for a transmitter.
68P81003Y71-O November 2002 5-21