Datasheet

www.symcom.com • 800-843-8848 • fax: 605-348-5685
42
Available Models:
Features:
Low, high and out-of-sequence alarms
Variable time delay / lag pump delay from
2-255 seconds
Duplex SPS (separate pump stop) pump
control
Duplex, triplex or quadplex pump control
Pump-up or pump-down functions
External silence, reset and alternation
configuration
Five-channel relay configuration
DIN rail or surface mountable
A
pprovals:
Specications
PC-105
The PC-105
is a 5-channel pump controller designed to handle
multiple pump applications. Alternatively, it can
operate as a 5-channel switch.
The PC-105’s control functions support all of the
popular industry-standard multi-pump pump-up
and pump-down configurations.
It can indicate low, high and out-of-sequence alarms
and use alternating and non-alternating pump
control. The non-alternating pump can be used as a
jockey pump or emergency pump.
Using the built-in DIP switches, individual pumps
can be disabled when taken out of service for repair
or maintenance.
For more information see:
See Appendix A, page 70, Figure 13 for dimensional
drawing.
Model PC-105
pump controller with duplex, triplex or quadplex functionality or 5-channel relay
Pump Controller
Input Characteristics
Supply Voltage ....................................120VAC
Frequency .........................................50*/60Hz
Functional Characteristics
Probe Sense Voltage ............................5vdc continuous
Output Characteristics
Relay Output Rating
Pilot Duty .........................................480VA @ 240VAC, B300
General Purpose ...................................7A @ 240VAC
General Characteristics
Temperature Range ................................-20° to 55°C (-4° to 131°F)
Maximum Input Power .............................4 W
Wire range ........................................12 to 20 AWG
Terminal Torque ....................................6 in.-lbs. (max.)
Pump In-rush delay ................................2 seconds
Standards Passed
Electrostatic Discharge (ESD) ........................IEC 61000-4-2, Level 3, 6kV contact, 8kV air.
Radio Frequency Immunity (RFI) .....................IEC 61000-4-3, Level 3, 10V/m
Fast Transients .....................................IEC 61000-4-4, Level 3, 4kV input power
2kV inputs/outputs
Safety Marks
UL ..............................................UL508 (File #E68520)
Dimensions .......................................3.703” W x 5.025” L x 2.35” H
(94.06 x 127.64 x 59.69mm)
Weight ............................................1.2 lbs. (19.2 oz., 544.31 g)
Mounting Method ..............................35 mm DIN rail or Surface Mount (#6 or #8 screws)
*Note: 50Hz will increase all delay timers by 20%.
CATALOG_SYMCOM_2014.indd 42 6/10/14 11:06 AM