Datasheet

www.symcom.com • 800-843-8848 • fax: 605-348-5685
30
Available Models:
Features:
Protects 3-phase motors from:
Loss of any phase (single phasing)
Phase reversal
Low voltage
High voltage
Voltage unbalance
Low frequency
High frequency
Rapid cycling
Built-in 3-digit display for programming, real-
time information and diagnostics
Programmable voltage and frequency settings/
parameters
Programmable restart control (adjustable
automatic restart or manual restart)
Reset pushbutton (and optional remote reset
pushbutton)
2 each separate programmable trip delay
timers and restart delay timers
Last four faults (with characteristics) available
via 3-digit display, network or remote displays
RS-485 Modbus network communications
Optional remote displays aid in complying
with arc-flash safety regulations
A
pprovals:
Specications
601
601-575
Auxiliary Products:
RS485MS-2W (communication module)
RM-1000/RM-2000 (remote displays)
777-MRSW (manual remote reset kit)
The Model 601
is a fully-programmable voltage monitor designed
to protect 3-phase motors. It can be used as a stand-
alone product or networked with an RM-1000,
RM-2000, PLC, computer or SCADA system.
When a harmful condition is detected, the
MotorSaver’s output relay is deactivated after the
specified trip delay. The output relay reactivates
after power line conditions return to an acceptable
level for the programmed restart delay (RD2).
The following 11 setpoints can be viewed from the
3-digit LED display or from a networked device:
low voltage, high voltage, voltage unbalance, low
frequency, high frequency, trip delay for voltage/
frequency faults, trip delay for single-phase faults,
rapid-cycle timer (RD1), restart delay after all
faults (RD2), type of restart after all faults (manual
or automatic), and RS-485 address. Six parameters
can be viewed as the motor is running: L1-L2
voltage, L2-L3 voltage, L1-L3 voltage, average
voltage, percent voltage unbalance and frequency.
When used with the RS485MS-2W communications
module, the Model 601 can communicate with most
modbus RTU master devices. Voltage conditions
can be monitored and setpoints can be changed
remotely using SymCom’s Solutions software, an
RM-1000, RM-2000 or other device.
For more information see:
See Appendix A, page 66, Figure 1 for dimensional
drawing.
See Appendix B, page 76, Figure 27 for typical
wiring diagrams.
Model 601
3-phase voltage & frequency monitor, on-board display, adjustable trip delay, optional
communications to PLC/SCADA/monitoring systems
3-Phase Voltage Monitor
Output Characteristics
Output Contact Rating
Pilot Duty .....................................480VA @ 240VAC
General Characteristics
Temperature Range .............................-20° to 70°C (-4° to 158°F)
Accuracy
Voltage ........................................±1%
Timing ........................................5% ±1 second
Repeatability
Voltage ........................................±0.5%
Maximum Input Power ..........................5 W
Transient Protection (Internal) ....................2500 V for 10 ms
Safety Marks
UL ............................................UL508 (File #E68520)
CSA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .C22.2 No. 14 (File #46510)
CE ............................................IEC 60947-6-2
Dimensions ....................................3.05 H x 3.85 W x 5.05 D in.
(77.47 x 97.79 x 128.27 mm)
Weight ........................................1.2 lbs. (19.2 oz., 544.31 g)
Mounting Method ..............................Surface mount (4 - #8 screws) or
DIN rail mount
SymCom’s Model 601 can be preprogrammed prior to installation by applying at least 120V
to the L1 and L2 terminals.
**575V Model
Input Characteristics
Line Voltage
601. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .190-480VAC
601-575 ........................................500-600VAC
Frequency .....................................50/60Hz
Functional Characteristics
Programmable Operating Points
LV - Low Voltage Threshold .....................170V (450V**) - HV Setting
HV- High Voltage Threshold .....................LV Setting - 528V (660V**)
VUB - Voltage Unbalance Threshold ..............2-15% or off
LF - Low Frequency Threshold ...................35Hz - HF Setting
HF - High Frequency Threshold ..................LF Setting - 75Hz
TD1 - Trip Delay for Voltage/
Unbalance/Frequency Faults ...............1-50 seconds
TD2 - Trip Delay for Single-Phase Faults ...........1-50 seconds
RD1 - Rapid-Cycle Timer ........................0, 2-500 seconds
RD2 - Restart Delay After All Faults. . . . . . . . . . . . . . .2-500 seconds
#RF - Type of Restart. . . . . . . . . . . . . . . . . . . . . . . . . . . .Manual or Automatic
ADDR - RS-485 Address .........................A01-A99
Fixed Reset Points
Overvoltage Reset ..............................97% of HV Setting
Low Voltage Reset ..............................103% of LV Setting
Voltage Unbalance Reset ........................UB Setting -1%
Low Frequency Reset ...........................LF Setting +0.6Hz
High Frequency Reset ...........................HF Setting -0.6Hz
CATALOG_SYMCOM_2014.indd 30 6/10/14 11:06 AM