User's Manual
Table Of Contents
- 1.Safety Precautions
- 2.System Description
- 2.1About This Manual
- 2.2Introduction
- 2.3System Features
- 2.4Physical Description
- 2.5System Description
- 2.6Consecutive Point Architecture
- 2.72 + 0 (East-West) Configuration
- 2.8Spanning Tree Protocol (STP)
- 2.91+1 Protection
- 2.101 + 1 Multi-hop Repeater Configuration
- 2.11Data Interfaces
- 2.12Crosspoint Switch
- 2.13Power Management
- 2.14Event-HD Software and Network Management
- 2.15System Loopbacks
- 3.Installation
- 3.1Unpacking
- 3.2Notices
- 3.3PRE-INSTALLATION NOTES
- 3.4Back-to-Back Bench Testing
- 3.5Overview of Installation and Testing Process
- 3.6Site Evaluation
- 3.7Installation of the Event-HD
- 3.8Quick Start Guide
- 3.9SDIDU™ Service
- 4.Summary Specification
- 5.Rear Panel Connectors
- 5.1DC Input (Power) Connector
- 5.2Ethernet 100BaseTX Payload Connector 1-2
- 5.3SONET Payload Connector
- 5.4STM-1 Payload Connector
- 5.5DVB/ASI, DS-3, E-3, STS-1 Payload Connector
- 5.6NMS 10/100BaseTX Connector 1-2
- 5.7Alarm/Serial Port Connector
- 5.8ODU Connector
- 5.9T1/E1 - Channels 1-2 Connector
- 5.10T1/E1 - Channels 3-16 Connector
- 5.11USB
- 5.12Voice Order Wire
- 5.13Data Order Wire
- 6.Appendix
4 6. Appendix
Alarm
Affected
Component
Description
LED to
RED
Alarm
Code
Severity
Power Supply
Card Removed
Lower
Power Supply The specified Power Supply
card has been removed from
the IDU. Fault detection via
card-detect logic.
N/A 32 Major
Power Supply
Fault Upper
Power Supply The Power Supply card has
indicated a fault. Fault
detection via polling GPIO.
Polling interval 5 sec.
N/A 36 Critical
Power Supply
Card Removed
Upper
Power Supply The specified Power Supply
card has been removed from
the IDU. Fault detection via
card-detect logic.
N/A 37 Major
Standard I/O
Card Removed
StdIO The Standard I/O card has
been removed from the IDU.
Fault detect via card-detect
logic.
N/A 41 Critical
Ethernet
Payload
Disconnect
StdIO There is no cable detected at
either Ethernet payload on
Standard I/O card (only if
Ethernet mode enabled). Fault
detection via polling of
Ethernet PHY. Polling interval
5 sec.
Standard
I/O
42 Critical
Framer
Initialization
Timeout
StdIO There is an initialization wait
for Framer to turn ON the
Framer Receiver side after
turning ON the Modem/ODU.
Fault detection via polling. Poll
only after timeout to detect.
Standard
I/O
43 Critical
Mini I/O Card
Removed
MiniIO The Mini I/O card has been
removed from the IDU (only if
Mini I/O card has been
enabled for use). Fault
detection via card-detect logic.
Standard
I/O
46 Critical
Mini I/O Card
Installed
MiniIO The Mini I/O card has been
installed into the IDU (only if
Mini I/O card is noted enabled
for use). Fault detection via
card-detect logic. Alarm is
raised then lowered.
Standard
I/O
47 Info
© 2007 Moseley, Inc. All Rights Reserved. 602-14886-01, Rev. A