Quick Specs
ZV36SSJSS – Monogram 36" Stainless Steel Professional Hood
Specification Revised 1/16
Optional Duct Cover Accessories
Optional Duct Cover Accessories
6" Duct Cover
12" Duct Cover
For answers to your Monogram,
GE Profile
™
Series or GE
®
Series appliance questions, visit
our website at GEAppliances.com or call
GE Answer Center
®
service, 800.626.2000.
Listed by
Underwriters
Laboratories
Advanced Planning
Ductwork Planning
• These vent hoods are equipped for 10" round ductwork. In most
instances they may be transitioned to 8" round.
• T his hood may be vented vertically through upper cabinets, soffit or
ceiling. A duct transition piece is supplied for vertical exhaust. Use
locally supplied elbows to vent horizontally through the rear wall.
• Determine the exact location of the vent hood.
• Plan the route for venting exhaust to the outdoors.
• Use the shortest and straightest duct route possible. For
satisfactory performance, duct run should not exceed 150 ft.
equivalent length for any duct configurations.
• Refer to “Duct Fittings” chart to compute the maximum permissible
length for duct runs to the outdoors.
• Use metal ductwork only.
• Install a wall cap or roof cap with damper at the exterior opening.
Order the wall or roof cap and any transition needed in advance.
Wall Framing for Adequate Support
• These vent hoods are heavy. Adequate structural support must
be provided. Hoods must be secured to vertical studs in the wall.
• It is strongly recommended that the vent hood with duct cover
be on site before final framing and wall finishing. This will also
help to accurately locate the ductwork and electrical service.
Decorative Duct Covers:
Decorative duct covers, 6" and 12" high, are available to fit all
models. The duct cover conceals the ductwork running from
the top of the hood to the ceiling or soffit. Stack one or more
duct covers over the top of the hood to reach your ceiling height.
POWER SUPPLY
IMPORTANT – (Please read carefully)
WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning
installation.
Do not use an extension cord or adapter plug with this appliance.
Follow national electrical codes or prevailing local codes and
ordinances.
Electric supply
These vent hoods must be supplied with 120V, 60Hz, and connected
to an individual, properly grounded branch circuit, and protected
by a 15 or 20 amp circuit breaker or time delay fuse.
• Wiring must be 2 wire with ground.
• If the electrical supply does not meet the above requirements,
call a licensed electrician before proceeding.
• Route house wiring as close to the installation location as possible
on the back wall or ceiling.
• Connect the wiring to the house wiring in accordance with
local codes.
Grounding instructions
The grounding conductor must be connected to a ground metal,
permanent wiring system, or an equipment-grounded terminal
or lead on the hood.
WARNING: The improper connection of the equipment-
grounding conductor can result in a risk of electric shock. Check
with a qualified electrician or service representative if you are in
doubt whether the appliance is properly grounded.
Decorative duct covers are available in 6" and 12" heights. Duct
covers may be stacked, in various combinations, to conceal the
ductwork running from the top of the hood to the ceiling.
• Before you begin, you should determine the installation height
of the hood and order the correct size duct cover. The duct
covers should be ordered at the same time as the vent hood
and be on site before installation. Order the duct cover
corresponding to your model.
6" Duct Covers
Hood Model 6" Duct Cover Dimensions
ZV36SSJSS ZX36DC6J
6"H x 15-3/4"W x 11-7/8"D
12" Duct Covers
Hood Model 12" Duct Cover Dimensions
ZV36SSJSS ZX36DC12J
12"H x 15-3/4"W x 11-7/8"D