Specifications
MOEN SPECIFIER SER VIC ES 1-800-321-8809 Ext. 2158
www.moen.com
Specifications
CRITICAL DIMENSIONS
(DO NOT SCALE)
36"
(912mm)
12"
(305mm)
FLOOR LINE
ESCUTCHEON
HANDLE
DIRECTION
OF HANDLE
ROTATION
6-3/4"
(171mm)
L
C
3" (76mm)
MIN. WALL
CAVITY
6'-6"
(1981mm)
NOMINAL
7" (178mm)
ESC. DIAM.
4-1/2” (114mm)
PLASTER GUARD
OPENING
2 1/2" MAX.
(63mm)
1/2" MIN. CC (13mm)
5/8" MIN. IPS (16mm)
FINISHED
WALL LINE
3-16" - 2"
H
C
F
O
3-7/16"
(87mm)
2-3/4"
(69mm) Min.
3"
(76mm)
Min.
Wall
Cavity
2-3/4"
(69mm)
Platerguard
Opening
5"
(127mm)
Esc.
Diameter
28-1/2"
NOMIMAL
(723mm)
FLOOR LINE
6'-6" (1981mm)
NOMINAL
DROP ELL
TUB RIM
FINISHED
WALL LINE
1/2-14 NPT
1/2-14
NPSL
THREAD
2" Dia.
3-3/16"SPRAY
HEAD
DIAMETER
9"SPRAY WAND
HEIGHT
DESCRIPTION
• Chrome plated metal construction
• Pressure balancing cycle valve design with 1/4 turn stops
• 3 function transfer valve
• 1/2” CC connections
• Contains: stationary showerhead, hand-held shower with non-positive pause,
69" metal hose, 30" slide bar, drop ell, and tub filler
Slide bar is NOT DESIGNED TO BE A GRAB BAR
• Applicable components are supplied with vandal resistant screws
OPERATION
• Temperature and transfer valves both have ADA compliant lever style handles
• Temperature handle operates counterclockwise through a 270° arc with off
at 6 o’clock, and the maximum hot at the 9 o’clock position
• Adjustable temperature limit stop
• Pressure balancing mechanism maintains selected discharge
temperature to ± 2°
• Transfer valve operates 3 distinct functions
FLOW
• 2.5 gpm (9.5L/min) hand-held shower and stationary shower head
CARTRIDGE
• 1222HD brass cartridge design in temperature control valve accommodates
back to back installations
• Brass construction with stainless steel materials
• Ceramic disc cartridge in transfer valve
STANDARDS
• Third party certified to ASME A112.18.1/CSA B125.1
and all applicable requirements referenced therein
• Backflow prevention compliance through ASME A112.18.3
•
ADA for lever handles
WARRANTY
• Warranted for 5 years against material or manufacturing defects
Three-Function Commercial
Tub/Shower System
Model: 8343
Rev. 8/14
NOTE: This valve is not intended to be used as a shut-off valve. To prevent the potential of cross flow, check valves must be integral to the supply valve or installed in both hot and cold water supply lines.
C O M M E R C I A L