Job Name:
System Reference: Date:
Fri
Mode Temp. Fan
Room
Cool Auto
Set temp.
Full View Basic View
CAPABILITIES
Basic Operations
On/Off
Operation Mode: Cool, Dry, Fan, Heat, Auto (Dual or Single set
point)
Set Temperature
Fan Speed
Daylight Savings Time (DST)
Vane setting: Auto, Step 1-5, Swing
Louver: Off, Swing On
Vent. (Lossnay): Off, Low, High
Manual vane angle: No Setting, Step 1-5, Draft reduction, All outlet
Draft reduction mode keeps the vane angle more horizontal than
the angle of Step 1
Restriction
Set Temperature range limit
Operation lock: On/Off, Mode, Set Temp, Vane
High power
Operate at higher-than-normal capacity to bring room to set
temperature quickly for up to 30 minutes
No Occupancy Auto-OFF
3D i-See sensor required
On/Off timer
Set On Time in 5-minute increments
Set Off Time in 5-minute increments
Repeat daily
Home screen display icon
Auto-Off timer
Automatically turns unit off after preset time
Time range of 30 to 240 minutes in 10-minute increments
Home screen display icon
Weekly timer
Set each day Monday through Sunday
1 to 4 time periods per day in 5-minute increments
Set Mode: On/Off/Auto (Dual set point)
On/Off/Auto
Set Temperature
Outdoor Unit silent mode
Schedulable: Mon, Tue, Wed, Thu, Fri, Sat, Sun
Start/Stop times in 5-minute increments
Silent Levels: Normal, Middle, Quiet
Energy saving features:
Automatic return to preset temperature setpoint if set point is
changed from the remote controller after a preset time range
Cool preset temp: Cool, Dry, Auto-Cool
Heat preset temp: Heat, Auto-Heat
Range of 30 to 120 minutes in 10-minute increments
Energy-saving Operation Schedule
Operation schedule
Four daily patterns with time periods in 5-minute increments and
energy-saving rate 0% to 90%
7 day programming
Night setback
Starts Heat/Cool operation when room temperature exceeds
preset temperature range
Adjustable time range in 5-minute increments
Main display
Full: Shows all icons and values
Basic: Limited to Mode, Set Temp., Fan, Time & Day
Backlight Display
Adjustable Contrast Level
Language: English, French, Spanish, Italian, Portuguese, Greek,
Turkish, Swedish
CITYMULTI
®
Function setting
Filter maintenance notification
Error code notification
*(All Capabilities are dependent on the model connected)
PAR-33MAA-J
MA REMOTE CONTROLLER
Specifications are subject to change without notice. Copyright © 2017 Mitsubishi Electric US, Inc.