Operator Manual Manuel de l’opérateur MBG1200 MBG3500 MBG5500 MBG6500 IMPORTANT – Please make certain that persons IMPORTANT - Prière de vous assurer que les who are to use this equipment thoroughly read and personnes destinées à utiliser cet appareil ont pris understand these instructions and any additional soin d'en lire et d'en comprendre le mode d'emploi instructions provided prior to operation. ou les directives avant de le mettre en marche. .
TABLE OF CONTENTS SAFTEY INSTRUCTIONS TOTAL WATTAGE, VOLTAGE AND INSTALLATION FEATURES AND CONTROLS PORTABILITY KIT INSTALLATION BEFORE OPERATION OPERATING THE GENERATOR MAINTENANCE STORAGE TROUBLE SHOOTING SPECIFICATION WIRING DIAGRAM EXPLODED DRAWING AND PARTS LIST LIMITED WARRANTY
SAFTEY INSTRUCTIONS DANGER WARNING CAUTION DANGER indicates a potentially WARNING indicates a potentially CAUTION indicates a potentially hazardous situation which, if not hazardous situation which, if not hazardous situation which, if not avoided, WILL result in death or avoided, could result in death or avoided, may result in minor or serious injury. serious injury. moderate personal injury, or property damage.
WARNING ENGINE AND MUFFLER MAY BE HOT Contact with muffler area can result in serious burns. Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire. ■ DO NOT touch hot parts and AVOID hot exhaust gases. ■ Allow equipment to cool before touching. U.S.
CAUTION Improper treatment of generator can damage it and shorten its life. To prevent surging that may possibly damage equipment, do not allow engine to run out of fuel when electrical loads are applied. Do not stick anything through ventilating slots, even when the generator is not operating. This can damage the generator or cause personal injury. The generator will do a better and safer job and give you much better service if it is used at the rate for which it was designed.
TOTAL WATTAGE, VOLTAGE AND INSTALLATION Total Wattage In order to prevent overloading and possible damage to your generator it is necessary to know the total wattage of the connected load. To determine which tools and/or appliances your generator will run follow these steps: 1. Determine if you want to run one item or multiple items simultaneously. 2. Check wattage requirements for the items you will be running by referring to the load’s nameplate or by calculating it (multiply amps x volts = watts). 3.
preventing backfeed into the power utility's electrical system. WARNING To avoid backfeeding into utility systems, isolation of the residence electrical system is required. Before temporary connection of a generator to the residence electrical system turn off the main switch. Before making permanent connections a double throw transfer switch must be installed. To avoid electrocution or property damage, only a trained electrician should connect generator to residence electrical system.
FEATURES AND CONTROLS 1. Fuel Tank Cap 2. Fuel Tank 3. Fuel Gauge 4. Fuel Tank Breathing Valve 5. Engine Choke Lever 6. Fuel Shut-off 7. Air Filter 8. Recoil Starter 9. Oil Gauge 10. Engine Shut-off 11. 120 V, 20 Ampere Duplex Receptacle(GFCI optional) 12. AC Protector 13. Circuit Breaker 13a. Hour Meter(optional) 14. 120/240 V, 20 Ampere Twistlock Receptacle 15. Ground Terminal 16. Oil Drain Plug 17. Muffler 18. Spark Arrester 19. Carbon Canister 20.
120V, 20 Ampere GFCI Duplex Receptacle(optional) If your generator comes with GFCI duplex receptacle, please follow below step: After starting the engine, check the GFCI for proper functioning by the following test procedure. ■ Push TEST button, The RESET button will pop out. Power is now off at the outlets protected by the GFCI, indicating that the device is functioning properly. ■ If TRIP does not appear when testing, do not use the generator. Call a qualified electrician.
Ground Terminal (15) Your generator needed to be properly connected to an appropriate earth ground to help prevent electric shock. A ground terminal connected to the frame of the generator has been provided for this purpose. Connecting a length of heavy gauge (12 AWG min.) copper wire between the generator Ground Terminal and a copper rod driven into the ground should provide a GROUND TERMINAL LOCATION: suitable ground connection.
PORTABILITY KIT INSTALLATION Step 1 Step 2 Step 3 Step 4 .
BEFORE OPERATION Check Engine Oil WARNING DO NOT attempt to start this engine without filling the crank case with the proper amount and type of oil. Your generator has been shipped from the factory without oil in the crankcase. Operating the unit without oil can damage the engine. Use class SE oil or a higher grade according to the table below. SAE 10W-30 or 10W-40 is recommended for general, all temperature use.
Check Engine Fuel WARNING DO NOT refuel while smoking or near open flame or other such potential fire hazards. Otherwise fire accident may occur. - Do not refill tank while engine is running or hot. - Close fuel cock before refueling with fuel. - Be careful not to admit dust, dirt, water or other foreign objects into fuel. - Wipe off spilt fuel thoroughly before starting engine. - Keep open flames away. Fill the tank with clean, fresh unleaded automotive gasoline - Check fuel level.
OPERATING THE GENERATOR Start the Generator 1. Disconnect all electrical loads from the generator 2. Set the circuit breaker to the “OFF” position. 3. Open the fuel shut off valve 4. Set the engine stop switch to the “ON” position. 5. Adjust choke lever Set the choke lever to “Choke” positon. Not necessary if the engine is warm 6. Pull the starter handle slowly until resistance is felt. This is the “compression” point.
7. As the engine warms up, readjust the choke lever to “OPEN” postion 8. Connect the load CAUTION When applying a load, do not exceed the maximum wattage rating of the generator when using one or more receptacles. Also, do not exceed the amperage rating of any one receptacle. Apply load only after generator is running. Voltage is regulated via CAUTION the engine speed adjusted at the Do not apply heavy electrical load during break-in factory for correct output.
MAINTENANCE 1. Maintenance Schedule ITEM REMARKS Spark Plug Engine Oil INITIAL EVERY EVERY Before Operation 25HR 50HR 100HR Check condition adjust gap and clean. Replace if ● necessary Check oil level ● Replace ● Air Filter Clean, replace if necessary Fuel Filter Clean and adjust. Replace if necessary Fuel Hose DAILY ● ● Check fuel hose for crack or damage. Replace if ● necessary Check for leakage. Retighten or Exhaust replace gasket if necessary System Check muffler screen.
c. Clean the oil on the panel. Dispose of used oil in local authority disposal site. Clean Spark Plug a. If the plug is contaminated with carbon, remove it using a plug cleaner and wire brush. b. Adjust the electrode gap to 0.7 to 0.8 mm. Engine GT241/400/600 GT1000/GT1300 Manufacturer NGK NHSP NGK Denso Champion Bosch Product No. BP6RSH E6RTC BPR5ES W16EPR RN11YC WR8DC+ Clean Air Filter a. Unscrew the air filter cover. b. Remove filter element and wash well in solvent. c.
STORAGE Besides drain fuel from fuel tank, the following procedures should be followed prior to storage of your petrol water pump for periods of 3 months or longer. 1. Turn fuel cock to “OPEN” position. 2. Loosen the drain screw on the side of the carburetor float chamber, and drain the fuel completely. NOTE 1) There are two screws on carburetor. The vertical one is the screw to hold the carburetor float chamber; the other one on the side of the carburetor float chamber is the drain screw.
TROUBLE SHOOTING NOTICE If your generator experiences a low engine oil condition, the engine will automatically shut off. Please check the oil first if you cannot start the generator. Condition Cause Insufficient compression Corrective Action Loose spark plug Tighten plug properly Loose cylinder head bolt Tighten bolt properly Damaged gasket Replace gasket 1. Insufficient pulling speed for Pull rope sharply No fuel starting rope supplied to 2.
- Engine oil is to 5W-30 4-stroke formulation (low temperature oil) instead of 10W-30 oil. - Pull the starter cord briskly 3 times, and then wait 15 seconds if the engine does not start. The delay of 15-seconds allows excessive fuel in the spark plug to vaporize. Failure to delay for 15-seconds pulling more than 3-times at one time may cause the spark plug to become flooded. If the spark plug becomes saturated with fuel, the engine will not start.
SPECIFICATION MODEL NO. MBG1200 SERIAL NO. MBG12AAC Emission Certification EPA Phase II Evaporation Certification None Alternator Type/Voltage regulation: Brush/AVR Frequency: 60 Hz Voltage: 120 V Rated Watts: 950 W Starting Watts: 1200 W Engine Brand: MITSUBISHI Engine Model NO.: GT241 Type: OHV, 4 Stroke, Air cooled Displacement: 79.6 cc Fuel Tank Size: 1.85 Gallon/Unleaded Gasoline Lubricating oil: .
MODEL NO. MBG3500 SERIAL NO. MBG35CAA MBG35CAB MBG35CAC Emission Certification EPA Phase III CARB EPA Phase II 49 states California None Evaporation Certification Alternator Type/Voltage regulation: Frequency: Voltage: Brush/AVR 60 Hz 120/240 V Rated Watts: 2800 W Starting Watts: 3500 W Engine Brand: Engine Model NO.: Type: MITSUBISHI GT600 OHV, 4 Stroke, Air cooled Displacement: 182 cc Fuel Tank Size: 4 Gallon/Unleaded Gasoline Lubricating oil: .
MODEL NO. MBG5500 SERIAL NO. MBG55CAA MBG55CAB MBG55CAC Emission Certification EPA Phase III CARB EPA Phase II 49 states California None Evaporation Certification Alternator Type/Voltage regulation: Frequency: Voltage: Brush/AVR 60 Hz 120/240 V Rated Watts: 5000 W Starting Watts: 5500 W Engine Brand: Engine Model NO.: Type: MITSUBISHI GT1000 OHV, 4 Stroke, Air cooled Displacement: 297 cc Fuel Tank Size: 7 Gallon/Unleaded Gasoline Lubricating oil: .
MODEL NO. MBG6500 SERIAL NO. MBG65CAA MBG65CAB MBG65CAC Emission Certification EPA Phase III CARB EPA Phase II 49 states California None Evaporation Certification Alternator Type/Voltage regulation: Brush/AVR Frequency: Voltage: 60 Hz 120/240 V Rated Watts: 6000 W Starting Watts: 7000 W Engine Brand: MITSUBISHI Engine Model NO.: Type: GT1300 OHV, 4 Stroke, Air cooled Displacement: 391 cc Fuel Tank Size: 7 Gallon/Unleaded Gasoline Lubricating oil: .
WIRING DIAGRAM
EXPLODED DRAWING AND PARTS LIST
LIMITED WARRANTY This Mitsubishi engine product carries a guarantee of 24 months. If your product develops a fault within this period, DO NOT return to store, you should, in the first instance contact our customer service. Not Covered: - Transportation charges for sending the product to the Company or its authorized service representative for warranty service, or for shipping repaired or replacement products back to the customer; these charges must be borne by the customer.
We warrant to the initial owner and each subsequent purchaser that the Warranted Parts shall be free from defects in materials and workmanship which causes the failure of the Warranted parts for a period of two years from the date the engine is delivered to a retail purchaser. 3.