Contents Section Introduction Page ................................................................... 3 Important Safety Information .................................................... 4 Pack Contents Checklist .......................................................... 6 Specifications ................................................................... 7 Installer Instructions ................................................................. 8 Installation ...........................................
Introduction Thank you for purchasing a quality Mira product. To enjoy the full potential of your new product, please take time to read this guide thoroughly. Having done so, keep it handy for future reference. The Mira Sport Thermostatic is an electric shower with separate controls for power selection and temperature/flow adjustment. A unique thermostatic valve stabilizes temperature changes caused by water pressure fluctuations. These can result from taps being turned on or off, or toilets being flushed.
Important Safety Information 1. Warning! 1.1. Products manufactured by us are safe and without risk provided they are installed, used and maintained in good working order in accordance with our instructions and recommendations. 1.2. THIS APPLIANCE MUST BE EARTHED. MAKE SURE SUPPLEMENTARY BONDING COMPLIES WITH THE "REQUIREMENTS FOR ELECTRICAL INSTALLATIONS". The installation must be in accordance with the current edition of BS 7671 "The IEE Wiring Regulations" in force at the time of installation.
2. Caution! 2.1. Follow all warnings, cautions and instructions contained in this guide, and on or inside the appliance. 2.2. The electrical installation must comply with the "Requirements for Electrical Installations” commonly referred to as BS 7671 the "IEE Wiring Regulations", or any particular regulations and practices, specified by the local electricity supply company in force at the time of installation.
Pack Contents Checklist 9 Tick the appropriate boxes to familiarize yourself with the part names and to confirm that the parts are included. 1. Mira Sport Thermostatic 9.0 and 9.8 kW 1 x Mira Sport Thermostatic 9.0 or 9.8 kW 1 x Olive 1 x Compression Nut 3 x Fixing Screws 3 x Wall Plugs 2 x Case Inserts 2.
3. Mira Logic Electric Shower Fittings 2 x Slide Bar End Supports 2 x Wall Plugs 2 x Slide Bar End Caps 2 x Fixing Screws 1 x Handset 1 x Applicator 2 x Hose Seals 1 x Slide Bar 1 x Clamp Bracket Assembly 1 x 1.25 m Flexible Hose 1 x Soap Dish/Hose Retaining Ring 1 x Soap Dish Collar Specifications 1. Plumbing 1.1. Minimum maintained inlet pressure of 70 kPa (0.7 bar). 100 kPa (1.0 bar) recommended for satisfactory operation. 1.2. Maximum static inlet pressure of 1000 kPa (10 bar). 1.3.
Installer Instructions Read the section “Important Safety Information” first. Plumbing Checklist 1. Minimum maintained inlet pressure = 70 kPa (0.7bar), 100 kPa (1.0 bar) recommended. Maximum static inlet pressure = 1000 kPa (10 bar). 2. Water treatment device (if required). 3. Free flowing isolating valve. 4. Positioned over water catchment area. 5. Fitted to finished wall surface. 6. No sharp hose kinks. 7. Fittings positioned with greater than 25 mm gap or outlet double checkvalve fitted.
Plumbing (checklist in detail) 1. The appliance is designed to operate with a minimum maintained inlet pressure of 70 kPa (0.7 bar), 100 kPa (1.0 bar) recommended, up to a maximum static inlet pressure of 1000 kPa (10 bar). 2. When installed in very hard water areas (above 200 ppm temporary hardness) your installer may advise the installation of a water treatment device, to reduce the effects of limescale formation. Your local water company will be able to advise the hardness of water in your area. 3.
Read the section “Important Safety Information” first. Electrical Checklist 1. Electrical supply fuse and consumer unit are adequate for the product. 2. Shower unit is earthed. 3. The minimum required supply cable size must conform to BS 7671. 4. Double pole isolating switch. 5. Do not twist live or neutral cable cores. 6. Electrical connections are tightly secured. Do not strain terminal block. 7. Plumbing supply completed before electrical supply is turned on.
Electrical (checklist in detail) 1. In a domestic installation, the rating of the electricity supplier's fuse and the consumer unit must be adequate for the additional demand. All Mira Sport electric showers are high power units, therefore it is essential to contact your electricity supplier to ensure that the supply is adequate for the product. Voltage drop due to local heavy demand will reduce the shower's performance. 2.
Installation Mira Sport Read the section “Important Safety Information” first. 1. 2. 200 mm 200 mm minimum gap from ceiling. Electrical supply is turned off at the mains. 4. Remove Cover and determine supply pipe position. 7. 3. 5. Remove three screws. 6. For back inlet use CAUTION! Do not drill into soldered elbow. buried cables or pipes. Do not trap green wire. 8. 9. Fix appliance to wall. Drill and plug* the Flush a minimum of three holes using 10 litres through template. pipework.
10. 11. Feed cable into Case. Fit Earth sleeve (not supplied) and strip insulation. Do not twist cable cores. Connect supply pipe. Do not overtighten! 12. 13. L = BROWN E = GREEN N = BLUE Firmly connect the conductors. Do not exert strain on the terminal block. 14. Make sure wires are clear of all mounting holes. 15. Refit the Service Tunnel and Cover. Make sure they fit correctly. Do not overtighten screws. Do not use alternative screws to secure the Cover.
Mira Logic Electric Shower Fittings 7 Read the section “Important Safety Information” first. Clamp Bracket 1. 2. Button Applicator Hose Retaining Ring 25 mm Minimum Slide Bar Spill-over level Depress button FULLY and assemble Clamp Bracket. Release button and remove Applicator. Position as shown to prevent back siphonage. 3. 4. Lock Features Slide the Soap Dish/Hose Retaining Ring and the Soap Dish Support Collar onto the Slide Bar below the Clamp Bracket.
6. 5. Mark the position of the middle slot on both top and bottom Supports. 7. CAUTION! Do not drill into buried cables or pipes. 8. First fix the bottom Slide Bar Support and fully tighten the screw*. Then fix the top Slide Bar Support whilst pressing it down, to keep the whole assembly together. Fit the End Caps to the Slide Bar Supports. 9. Fit the Hose to both the Handset and the Shower Outlet, remembering to pass it through the Soap Dish/Hose Retaining Ring.
Commissioning If you are unsure how an electric shower works, please read through the User Instructions section before continuing. 1. 2. Electrical supply is turned off at the mains. 4. 3. Turn control to full cold. 5. Check for water leaks. 7. Turn water supply fully on. 6. Set control to LOW. 8. Switch on electrical supply. Light on the appliance comes on. 9. 0 - 15 secs Push START button. Light remains on Water will be flowing at a cool temperature. 10.
11. 12. 5 - 10 secs Set control to HIGH. 13. The temperature will rise further. 14. Adjust temperature as required. Flow rate will adjust automatically. 15. Press STOP button. Shower will continue to run for a few seconds before stopping, light remains on. Isolate power, light goes out. 16. 0 - 5 secs The shower will purge water from its tank for a few seconds. Residual water may drain over a few minutes. Note! A slight hissing sound may be heard from the Mira Sport during operation.
User Instructions 1. Warning! 1.1. DO NOT operate this appliance if it appears to be frozen. Allow the appliance to thaw and then contact your installer before using again. 1.2. DO NOT operate this appliance if water leaks from the pressure relief valve; maintenance will be required before the appliance can be safely used. 1.3. There are no user serviceable components beneath the cover of this appliance. Only a competent tradesperson should remove the cover. 1.4.
How Your Electric Shower Works Heated water is produced by adjusting the flow of cold water passed through a heater tank. The shower has three heater settings. The warmer the shower, the lower the flow rate and vice versa.
The Effect of Seasonal Changes For a cold shower select LOW. For a summer warm shower select MEDIUM. For a winter warm shower select HIGH. During extremes of mains water supply temperature, adjust heater setting to obtain a better showering temperature. The Effect of Other Water Devices Example of how shower temperature stabilizes due to pressure changes. Water inlet pressure fluctuations due to other draw offs (e.g. flushing toilet).
Using Your Shower Read the section “Important Safety Information” first. 1. 2. Switch on electrical supply. Light on the appliance comes on. Press START button. Light remains on. 3. 4. Set to desired position. Check water temperature before entering shower. 5. Allow 10-15 seconds for any temperature adjustments to reach the handset. 6. 7. Press STOP button. Shower will continue to run for a few seconds before stopping, light remains on. Isolate power, light goes out.
Changing the Spray Setting The handset has four different spray settings (Start, Soothe, Force and Eco). 1. 2. Soothe Turn the Spray Plate anticlockwise until it "clicks". Water will flow from the large diameter holes. Start Turn the Spray Plate anticlockwise until it "clicks". Water will flow from the outer set of holes. 4. 3. Eco Turn the Spray Plate fully clockwise. Water will flow from the outer set of holes. Force Turn the Spray Plate anticlockwise until it "clicks".
Fault Diagnosis The trouble shooting information tabled below gives details on probable causes and remedies should difficulties be encountered whilst the shower is in operation. Warning! There are no user serviceable components beneath the cover of the appliance. ONLY A COMPETENT TRADESPERSON SHOULD REMOVE THE FRONT COVER! Symptom Power Low Light Flow Light Heater Setting Low/ Medium/ High Appliance fails to operate.
Symptom Power Low Light Flow Light Heater Setting Low/ Medium/ High Unable to ON select a cool enough shower. High OFF Probable Cause Possible Remedy Due to a rise in mains water supply temperature, the Heater setting may be too high. Turn the Heater Selector knob to Medium and adjust the Temperature control until a suitable temperature is achieved. ALL OF THE FOLLOWING REMEDIES MUST ONLY BE PERFORMED BY A COMPETENT TRADESPERSON! Handset dripping. Low or No flow.
Symptom Power Low Light Flow Light Heater Setting Low/ Medium/ High Probable Cause Possible Remedy ON ON Any Other outlets (e.g. toilet, garden hose, washing machine, etc.) drawing water while the shower is being used. Turn off other appliances whilst shower is in use. ON OFF Any Handset blocked. Remove and clean. ON OFF Any Service tunnel or cover not fitted correctly causing Start/Stop button not to operate. Check case inserts are cut and fitted correctly.
Symptom Power Low Light Flow Light Heater Setting Low/ Medium/ High Probable Cause Possible Remedy No change ON in temperature ON between Low/ Medium/ High setting. ON Any Insufficient mains water pressure. Contact local water company. OFF Any Possible failure of Microswitch or Heater Tank. Use a suitable continuity device to check the continuity of the Microswitch or Heater Tank and replace parts as necessary. Water will not turn off.
Maintenance Handset - Cleaning Clean with mild washing up detergent or soap solution. Wipe dry with soft cloth. Poor shower performance can be avoided by cleaning spray plate. Use thumb or soft cloth to wipe rubber nozzles. The Handset must also be descaled regularly. Inlet Filter - Cleaning/Renewing Read the section “Important Safety Information” first. 1. 3. 2. Electrical supply is turned off at the mains. Turn water supply fully off. 4. Remove three screws, Cover and Service Tunnel. 5.
Dimensions 205 mm 85 mm 369 mm 344 mm 659 mm 28
E N L Power On Neon Start/Stop Solenoid Valve Internal Wiring Diagram Inlet Connector Tank Connection Low Flow Neon Pressure/Power Selector Switch Thermal Cutout Dual Disc Load Wiring Diagram
Accessories DCV-H: An outlet double check valve, designed to prevent the backflow or backsiphonage of potentially contaminated water, through shower controls which are fitted with a flexible hose as part of the outlet shower fitting. Available as an optional accessory from all Mira Showers stockists. Spare Parts Mira Sport Thermostatic Spare Parts List (see diagram on next page) 405.58 406.27 416.38 416.41 416.48 416.51 872.01 872.28 1563.509 1563.514 1563.519 1563.522 1563.532 1563.533 1563.534 1563.
Mira Sport Thermostatic Spare Parts Diagram 1563.519 B B B 416.41 1563.509 B A 1563.546 1563.532 1563.533 B 1563.514 872.01 872.28 A B 1563.538 406.27 1563.536 1563.540 A 405.58 A 416.48 416.38 1563.542 416.51 1563.534 1563.543 Important Note! Push-fit connectors must be assembled back to back onto terminals of micro-switches. 4 mm MINIMUM A minimum air gap of 4 mm must be maintained between the connectors after assembly.
Mira Logic Electric Shower Fittings Spare Parts List 450.01 450.03 450.06 450.08 450.17 450.26 450.28 450.36 632.73 1563.257 1563.552 Hose 1.
Mira Logic Electric Shower Fittings Spare Parts Diagram D B 1563.257 A 450.28 450.36 450.03 632.73 450.06 1563.552 450.
Notes 34
Notes 35
Customer Service UKAS 1060735-W2-A (J95E/F) 36 © Kohler Mira Limited, April 2006