Specifications
<Point Clearing Procedure>
•
Initialize Points (PJ2)
1. Turn the Power Switch OFF.
2. With the PJ2I points (1, 2) shorted, turn the Power Switch ON.
•
Memory Clear Test Point (TP2)
1. Turn the Power Switch OFF.
2. With the TP1 and TP2 points shorted, turn the Power Switch ON.
• When incorrect display/incorrect operation has occurred, reset and clear it in the following
sequence:
Initialize Points (PJ2) → Memory clear Test Point (TP2)
• When memory has been cleared, each mode must be set again (see below).
NOTES
<List of Data Cleared by the Switch and Points>
Front Door
Open/Close
Trouble Reset
Switch S1
Initialize
Points PJ2
Memory
Clear Test
Point TP2
Jam display O — O —
Trouble display
(other than Exposure/Fusing)
O—O—
Trouble display
(Exposure/Fusing only)
—OO—
Incorrect display/incorrect operation — — O O
Copy mode program — — — O
User’s choice — — — O
Tech. Rep. choice — — — O
F5/F7 setting — — — O
System setting — — — O
ADF setting — — — O
Level history — — — O
RD mode setting — — — O
Admin. mode — — — O
Adjust mode — — — O
O: Cleared. —: Not cleared.
Note: When memory has been cleared, "Level History" must be selected and the required value
entered into "ATDC Set".
Data Cleared
Clearing Method
S-10