Specifications

20-2. Suction Fan Motor M18 Control
Suction Fan Motor M18 turns at either half or full speed, selected by the
signal output from pin 49 of IC5A on Master Board PWB-A. It is controlled at
the following timings.
<M18 Half Speed Rotation Timing>
At the same time when Power Switch S1 is turned ON, M18 turns at half
speed.
The speed of M18 rotation is switched from full to half approx. 4,600
msec. after the trailing edge of the last copy has moved past Paper Exit
Sensor PC36.
<M18 Full Speed Rotation Timing>
The speed of M18 rotation is switched from half to full at the same time
when PC Drum Drive Motor M5 is energized (p. M-XX).
= Timing Chart =
Power Switch S1
1075T101CB
ON
IC5A-49
M18
4600 msec
M5 : ON
Trailing Edge of Last Copy Moves Past PC36
Half-Speed
Rotation
Full-Speed Rotation
Half-Speed
Rotation
1075C20MAA
M-163