Installation Sheet

INSTALLATION INSTRUCTION FOR 1425
WARNING! SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER .
AVERTISSEMENT! COUPER LE COURANT AU NIVEAU DES FUSIBLES OU DU DISJONCTEUR.
EAD AND SAVE THESE INSTRUCTIONS
ASSEMBLING THE FIXTURE (Fig.2)
1. Shut off the power at the circuit breaker and remove the old
fixture, including the mounting hardware.
2. Carefully remove the fixture from the carton and check that
all parts are included as shown in the illustration.
3. Thread the loop (J) onto the nipple (K).
4. Spread the arms (K1) so that the arms (K1) are at equal
distance from each other.
5. Place the glass (Q) over the socket (P), and secure in
place with the socket ring (R).
6. Allow the nipple (L) to pass through the hole of the panel
(M) and the cap (N), then secure with the finial (O).
HANGING THE FIXTURE (Fig.1)
7. Thread the nipple (E) into loop (H) until snug.
8. Thread hex nut (D) onto nipple (E). Place lock washer (C)
over end of nipple (E) protruding through mounting bar.
9. Thread other end of nipple (E) with screw collar loop (H)
into the crossbar (A) until snug.
10. Take this crossbar (A) assembly and mount to ceiling
junction box with the mounting screws (B) (Size: #8-
32*0.6”L). The side of the mounting bar marked “GND”
must face out.
11. Using proper chain pliers to open one end link of the chain
(I) and connect to the loop (J). Close the link (Fig.1).
12. By measuring, determine correct number of links needed
for desired hanging height. Using proper chain pliers,
disconnect and discard remaining chain.
13. Lace the fixture wires through the chain links. Slip loop
collar (G) and canopy (F) over the chain.
14. Open the other end of the chain (I) and connect to loop (H).
Close the link.
15. Feed the fixture wires through the loop (H), and nipple (E)
and pull until taut.
CONNECTING THE WIRES (Fig.3)
16. At this point, connect the electrical wires as shown in Fig.
3, making sure that all wire connectors are secured. If your
outlet box has a ground wire (green or bare copper),
connect the fixture’s ground wire directly to the mounting
plate using the green screw provided. After the wires are
connected, tuck them carefully inside the outlet box.
COMPLETING THE INSTALLATIONS (Fig. 1)
17. Raise the canopy (F) all the way to the ceiling. Raise the
loop collar (G) and thread onto collar loop (H) protruding
through canopy (Fig.1)
Install the light bulb(s) in accordance with the fixture’s
specification. DO NOT EXCEED THE MAXIMUM
WATTAGE RATING! (NE PAS DEPASSER LA
PUISSANCE NOMINALE MAXIMALE!).
Your installation is now complete. Return power to the junction
box and test the fixture.
Note: Illustration (Fig.2) on this manual is for installation
purposes only. It may or may not be identical to the fixture
purchased.
Fig.1
Fig.2
Set#
-
-
-
Crossbar
Ground screw
Mounting screw*2
A 016
Chain#
HCH2072-281
(3.8mm)

Summary of content (1 pages)