User's Manual
54
Amps
5.5
5.5
5.5
5.5
5.5
5.5
5.5
No Load
RPM
0-2800
without RAD 0-850
RAD low 0-565
RAD high 0-1275
without RAD 0-850
RAD low 0-565
RAD high 0-1275
0-850
0-850
without RAD 0-850
RAD low 0-565
RAD high 0-1275
without RAD 0-600
RAD low 0-400
RAD high 0-900
Volts
AC
120
120
120
120
120
120
120
Cat.
No.
0233-20
0234-1
0234-6
0235-21
0235-6
0236-6
0244-1
Amperes
Double Insulated
Symbology
Canadian Standards
Association
Underwriters
Laboratories, Inc.
Volts Alternating
Current
No Load Revolutions
per Minute (RPM)
Specifications
Right Angle Drive Unit Cat. No. 48-06-2871
Mexican Approvals
Marking
FUNCTIONAL DESCRIPTION
3
1. Chuck
2. Nameplate
3. Trigger
4. Forward/Reverse
switch
5. Side handle
5
1
2
4
The grounding prong in the plug is con-
nected through the green wire inside the
cord to the grounding system in the tool.
The green wire in the cord must be the
only wire connected to the tool's ground-
ing system and must never be attached to
an electrically “live” terminal.
Your tool must be plugged into an appro-
priate outlet, properly installed and
grounded in accordance with all codes and
ordinances. The plug and outlet should look
like those in Figure A.
Double Insulated Tools:
Tools with Two Prong Plugs
Tools marked “Double Insulated” do not re-
quire grounding. They have a special
double insulation system which satisfies
OSHA requirements and complies with the
applicable standards of Underwriters Labo-
ratories, Inc., the Canadian Standard As-
sociation and the National Electrical Code.
Double Insulated tools may be used in ei-
ther of the 120 volt outlets shown in
Figures B and C.
Grounded Tools:
Tools with Three Prong Plugs
Tools marked “Grounding Required” have
a three wire cord and three prong ground-
ing plug. The plug must be connected to a
properly grounded outlet (See Figure A). If
the tool should electrically malfunction or
break down, grounding provides a low re-
sistance path to carry electricity away from
the user, reducing the risk of electric shock.
Fig. B
Fig. C
Fig. A
Improperly connecting the
grounding wire can result in the
risk of electric shock. Check
with a qualified electrician if you
are in doubt as to whether the
outlet is properly grounded. Do
not modify the plug provided
with the tool. Never remove the
grounding prong from the plug.
Do not use the tool if the cord or
plug is damaged. If damaged,
have it repaired by a MILWAUKEE
service facility before use. If the
plug will not fit the outlet, have a
proper outlet installed by a
qualified electrician.
GROUNDING
WARNING!