SDS

Page3of8 58970500
LithiumionBattery‐Rechargeable
14A
PRODUCTSOFCOMBUSTION:
Organiccomponentswillburnifincinerated.CombustionofcellcontentsmaycauseevolutionofHydrogenFluoride.Incaseof
fireinanadjacentarea,usewater,CO2,ordrychemicalextinguishersifcellsarepackedintheiroriginalcontainerssincethe
fuelofthefireisbasicallypaper
products.
PROTECTIONOFFIREFIGHTERS:
HydrofluoricAcidexposureduringfirefighting:Thisinformationisgivenfortheuseofprofessionalfirefightersrespondingtoa
warehousefirewherefirefromothermaterialsmayincineratebatteries.Thissectionisprovidedsolelyincaseofexposure,
duringfirefighting,tothecombustionbyproducts.
SECTION6:ACCIDENTALRELEASEMEASURES
PERSONALPRECAUTIONS:
Usestandardindustrialclothinginnormaluse.Ifhandlinglargecontainersofcellswearsteeltoedfootwear.
ENVIRONMENTALPRECAUTIONS:
Nospecialprecautionsnecessary.
METHODSFORCONTAINMENT:
Transportcontaineroutdoors.Holdburnedcellsandfirecleanupsolidsfordisposalaspotentialhazardouswaste.Unburned
cellsarenot
hazardouswaste.Afirewithover100kgofcellsburntwilllikelyrequirereportingtoenvironmentalofficials.
Alwaysconsultandobeyallinternational,federalandlocalenvironmentallaws.
METHODSFORCLEANUP:
Nodataavailable
OTHERINFORMATION:
Nodataavailable
SECTION7:HANDLINGANDSTORAGE
HANDLING:
Useonlyapprovedchargingequipment.Donotdisassemblebatteryorbatterypack.Donotpuncture,crushordisposeofinfire.
STORAGE:
Storeinacool,dryplaceawayfromsparksandflame.Keepbelow125°C.Keepabove‐60°C.Chargebetween0°Cand45°C.
SECTION8:EXPOSURECONTROLS/PERSONALPROTECTION
ChemicalName
OSHA
PEL
ACGIH
TLV
CaliforniaProp65
Reg.Y/N
IARC/NTP
Y/N
AluminumFoil TWA
5mg/m
3
*
TWA
5mg/m
3
*
N N
Biphenyl(BP) NA NA N N
CopperFoil NA NA N N
Linear&CyclicCarbonatesolvents NA NA N N
GraphitePowder/Carbon NA NA N N
MetalOxideorotherElectrolyte(proprietary) NA NA N N
LithiumHexaflurophosphate(LiPF
6