Page 3 of 9 58970500
Lithiumion Battery Rechargeable
10A
SECTION 5: FIRE FIGHTING MEASURES
SUITABLE EXTINGUISHING MEDIA:
Water spray, carbon dioxide, dry chemical powder or appropriate foam. Use agent appropriate for surrounding materials.
UNSUITABLE EXTINGUISHING MEDIA:
None.
PRODUCTS OF COMBUSTION:
Organic components will burn if incinerated. Combustion of cell contents may cause evolution of Hydrogen Fluoride. In case of
fire in an adjacent area, use water, CO2, or dry chemical extinguishers if cells are packed in their original containers since the
fuel of the fire is basically paper products.
PROTECTION OF FIREFIGHTERS:
Hydrofluoric Acid exposure during firefighting: This information is given for the use of professional fire fighters responding to a
warehouse fire where fire from other materials may incinerate batteries. This section is provided solely in case of exposure,
during firefighting, to the combustion byproducts.
SECTION 6: ACCIDENTAL RELEASE MEASURES
PERSONAL PRECAUTIONS:
Use standard industrial clothing in normal use. If handling large containers of cells wear steeltoed footwear.
ENVIRONMENTAL PRECAUTIONS:
No special precautions necessary.
METHODS FOR CONTAINMENT:
Transport container outdoors. Hold burned cells and fire cleanup solids for disposal as potential hazardous waste. Unburned
cells are not hazardous waste. A fire with over 100 kg of cells burnt will likely require reporting to environmental officials.
Always consult and obey all international, federal and local environmental laws.
METHODS FOR CLEAN‐UP:
No data available
OTHER INFORMATION:
No data available
NFPA