Installation plan Washing machine PWM 908 DV/DP To avoid the risk of accidents or damage to the machine, it is essential to read operating and installation instructions before installation and commissioning. This prevents both personal injury and damage to the machine.
United Kingdom Miele Co. Ltd. Fairacres, Marcham Road Abingdon, Oxon, OX14 1TW Professional Sales, Tel.: 0845 365 6608 E-mail: professional@miele.co.uk Website: www.miele.co.uk/professional Australia Miele Australia Pty. Ltd. ACN 005 635 398 ABN 96 005 635 398 Ltd. 1 Gilbert Park Drive Knoxfield, VIC, 3180 Tel.: 1300 731 411 Website: www.miele-professional.com.au E-mail: info@miele-professional.com.au South Africa Miele (Pty) Ltd. 63 Peter Place, Bryanston 2194 P.O. Box 69434, Bryanston 2021 Tel.
PWM 908 en-GB Appliance dimensions 11 276 340/05 3
PWM 908 en-GB Installation 4 11 276 340/05
PWM 908 en-GB Washer-dryer stack 11 276 340/05 5
PWM 908 en-GB Installation B B B B BS 145,5 148 305 148 681 1031 305 1031 145,5 B B B B BS 145,5 6 305 145,5 148 305 148 11 276 340/05
PWM 908 en-GB Installation 11 276 340/05 7
PWM 908 en-GB Technical data Drum volume l PWM 908 DV 73 PWM 908 DP 73 Load capacity kg 8.0 8.0 Door opening diameter mm 300 300 Max. spin speed rpm 1600 1600 704 704 48 48 g-factor Residual moisture (standard load per DIN 60456) % Electrical connection (EL) Standard voltage 2N AC 400 V 2N AC 400 V Frequency Hz 50 50 Total rated load kW 5.5 5.5 Fuse rating (B trip rating according to EN 60898) A 2 x 16 2 x 16 Supply lead min. cross-section mm² 4 x 1.5 4 x 1.
PWM 908 en-GB Technical data PWM 908 DV PWM 908 DP Variations in the following countries: Standard voltage 13 A (GB only) 2N AC 400 V 2N AC 400 V Frequency Hz 50 50 Total rated load kW 5.5 5.5 Fuse rating (B trip rating according to EN 60898) A 2 x 13 2 x 13 Supply lead min. cross-section mm² 4 x 1.5 4 x 1.5 2000 2000 Supply lead without plug Length of supply lead mm Alternative voltage (convertible) 1N AC 230 V 1N AC 230 V Total rated load kW 2.85 2.
PWM 908 en-GB Technical data Alternative voltage (convertible) PWM 908 DV 2N AC 400 V PWM 908 DP 2N AC 400 V Total rated load kW 5.5 5.5 Fuse rating (B trip rating according to EN 60898) A 2 x 16 2 x 16 Supply lead min. cross-section mm² 4 x 1.5 4 x 1.5 Standard voltage (AUS only) 1N AC 230 V 1N AC 230 V Frequency Hz 50 50 Total rated load kW 5.5 5.5 Fuse rating A 1 x 25 1 x 25 Supply lead min. cross-section mm² 3 x 2.5 3 x 2.
PWM 908 en-GB Technical data PWM 908 DV PWM 908 DP Drain pump (DP) Hose connection (external diameter) mm - 22 (DN 22) Max. drainage temperature °C - 90 On-site hose sleeve (int. diameter x length) mm - 22 x 30 Max. transient flow rate l/min - 26 Max.
PWM 908 en-GB Technical data PWM 908 DV PWM 908 DP Machine data Overall machine dimensions (H/W/D) mm 850/605/714 850/605/714 Casing dimensions (H/W/D) mm 850/596/678 850/596/678 mm 900/605 900/605 Min. side gap mm 20 20 Recommended side gap – washer-dryer stack mm >300 >300 Min. distance to opposite wall from machine front mm 950 950 Recommended distance to opposite wall from machine front mm 1100 1100 Machine weight (net weight) kg 103 103 Max.
PWM 908 en-GB Installation and planning notes Installation requirements Electrical connection should only be made to a power supply provided in accordance with all appropriate local and national legislation and regulations.
PWM 908 en-GB Securely connect the drain hose to a sink drain outlet Interface The drain hose can be connected securely to a suitable sink drain outlet. The appliance can be fitted with an XKM 3200 WL PLT communication module. This module can be used as a WiFi or LAN interface. The LAN interface provided via the module complies with SELV (Safety Extra Low Voltage) in accordance with EN 60950. Connected appliances must also comply with SELV.