Installation Plan

Technical datasheet
Tumble dryer:
Heating:
PT 8337
Electric (EL)
Legend:
Abbreviations in bold type:
Connection required
en - US
Abbreviations in circle with dashes:
Connection optional or required depending on model version
Optional extras:
BS
Concrete base
Quality and density of concrete must comply with load.
Concrete base must be firmly secured to floor!
Recommended height
4”
100 mm
Minimum height
2”
50 mm
Minimum width
35 3/8
900 mm
Minimum depth
43 1/4
1100 mm
Machine connections:
Electrical
connection
Standard voltage
3 AC 208 V
Frequency
60 Hz
Rated load
52582 BTU/h
15.4 kW
Fuse rating
3 x 65 A
Connection cable, min. cross-section
4 x AWG 6
4 x 10 mm²
Connection cable to be ordered separately
Electrical connection must comply with national regulations.
Connection using multi-pole wall socket in compliance with IEC/EN 60309 and IEC/EN 60947 is
recommended in order to simplify electrical tests.
If machines are hard-wired, a multi-pole switch must be provided on site.
A wall socket or isolator must be accessible after installation.
Installation plan: PT 8337 EL
Date: 18-May-2015 Page: 13
Convertible to
3 AC 220 - 240 V
60 Hz
59070 -
69654 BTU/h
17.3 -
20.4 kW
Frequency
Rated load
Fuse rating
3 x 65 A
Connection cable, min. cross-section
4 x AWG 6 4 x 10 mm²
Connection cable to be ordered separately