Installation Instructions Gas Cooktop KM 360 ® To prevent accidents and machine damage, read these instructions before installation or use. ® UV M.-Nr.
WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death. – Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. – WHAT TO DO IF YOU SMELL GAS ß Do not try to light any appliance. ß Do not touch any electrical switch. ß Do not use any phone in your building. ß Immediately call your gas supplier from a neighbor’s phone.
Contents IMPORTANT SAFETY INSTRUCTIONS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Appliance dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Setting the cooktop into place . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 Securing the cooktop. . . . . . . . . . . . . . .
IMPORTANT SAFETY INSTRUCTIONS Installation The minimum distances given in these Installation instructions are to combustible surfaces, and must be observed to ensure safe operation. Failure to do so increases the risk of fire. The cabinetry and venting hood should be installed first to prevent damage to the cooktop. recommended Gas appliances should only be installed in a well ventilated area. The countertop must be bonded with heat resistant (212 °F/100 °C) adhesive to prevent distortion or dissolving.
IMPORTANT SAFETY INSTRUCTIONS The cooktop must not be installed over a dishwasher, washer, dryer, refrigerator or freezer. Heat radiated by the cooktop may damage the appliances. Deep fat fryers must not be installed next to gas cooktops. Gas flames can ignite splattering oil. A distance of at least 12" (305 mm) should be maintained between these two appliances. The minimum distance between two cooktops must be 4" (100 mm).
Appliance dimensions a Built in depth b Electrical connection box c Gas connection R ½" NPT ^ Rember to maintain the minimum safety distances to combustible surfaces: - 2 3/4" (70 mm) between the cut-out and the back wall and - 12" (305 mm) between the cut-out and a side wall or tall unit to the right or left of the cut-out. (See "Important Safety instructions").
Installation Setting the cooktop into place Securing the cooktop ^ Screw the gas regulator onto the nipple underneath the cooktop. For convenience, an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas connection and the regulator. For more information see "Gas connection - Gas pressure regulator". The included gas regulator must be installed between the cooktop and the gas shut off valve.
Electrical connection This appliance must be electrically grounded. All electrical work should be performed by a qualified electrician in accordance with local or national codes and the: - National Electrical Code ANSI / NFPA No. 70 for the USA or - Canadian Electrical Code Part I for Canada (CSA Standard C 22.2 No. O-M91). ,WARNING Disconnect the appliance from the main power supply before installation or service.
Gas connection Installation and service must be performed by a qualified installer, service agency or the gas supplier. The gas connection must be made in accordance with local codes or in the absence of local codes with: In Massachusetts a licensed plumber/gas fitter is required. - This appliance must be installed with its own shut off valve and the included gas pressure regulator.
Gas connection Gas pressure regulator A pressure regulator that is convertible from natural to LP gas (Propane) or vice versa is included with the appliance. The included regulator corresponds with the gas type of the cooktop. Verify before installing. The adjusted pressure is: natural gas - 4" w.c. LP gas - 10" w.c. For convenience, an AGA or CGA approved flexible stainless steel gas hose (accordion type) may be used between the gas connection and the regulator.
Gas connection Nominal Rating Table NG (Natural gas) LP (Liquid propane gas) Auxiliary burner BTU/hr kW Max. output 3400 1.0 Min. output 900 0.26 Max. output 6000 1.76 Min. output 1200 0.35 Max. output 10200 3.0 Min. output 1700 0.5 25600 7.5 Normal burner Fast burner All burners Max.
Converting to another type of gas The cooktop should have been ordered for connection to either natural gas or LP gas (propane). If the cooktop is not configured for the proper type of gas connection please contact your Miele Dealer.
Alterations rights reserved / 4606 M.-Nr.