Operating and Installation Instructions Ventilation hood To prevent accidents and damage to the appliance, you must read these instructions before installing the appliance and using it for the first time. en-US M.-Nr.
Contents IMPORTANT SAFETY INSTRUCTIONS................................................................. 4 Caring for the environment ................................................................................. 13 Description of functions ...................................................................................... 14 Con@ctivity 2.0 function ........................................................................................ 15 Guide to the appliance........................................
Contents Installation Instructions .......................................................................................... 31 Disassembly........................................................................................................... 31 Installation parts..................................................................................................... 32 Appliance dimensions............................................................................................
IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS This appliance complies with current safety requirements. Improper use of the appliance can lead to personal injury and material damage. Read all instructions before installing or using the appliance for the first time. Only use the appliance for its intended purpose. Keep these operating instructions in a safe place and pass them on to any future user. Use CAUTION: For General Ventilating Use Only.
IMPORTANT SAFETY INSTRUCTIONS Children As with any appliance, close supervision is necessary when used by children. Please supervise children in the vicinity of the hood and do not let them play with it. Danger of suffocation! Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children.
IMPORTANT SAFETY INSTRUCTIONS Be certain your appliance is properly installed and grounded by a qualified technician. To guarantee the electrical safety of this appliance, continuity must exist between the appliance and an effective grounding system. It is imperative that this basic safety requirement be met. If there is any doubt, have the electrical system of the house checked by a qualified electrician.
IMPORTANT SAFETY INSTRUCTIONS Defective components should be replaced by Miele original parts only. Only with these parts can the manufacturer guarantee the safety of the appliance. If the power cord is damaged, it must only be replaced by a qualified service technician. During installation, maintenance, and repair work, the ventilation hood must be disconnected from the electrical supply.
IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF INJURY TO PERSONS IN THE EVENT OF A COOKTOP GREASE FIRE, OBSERVE THE FOLLOWING*: – a) SMOTHER FLAMES with a close fitting lid, cookie sheet, or metal tray then turn off the burner. BE CAREFUL TO PREVENT BURNS. If the flames do not go out immediately, EVACUATE AND CALL THE FIRE DEPARTMENT. – b) NEVER PICK UP A FLAMING PAN - You may be burned. – c) DO NOT USE WATER, including wet dishcloths or towels - a violent steam explosion will result.
IMPORTANT SAFETY INSTRUCTIONS Overheated oils and fats can ignite and set the ventilation hood on fire. When cooking with oils or fats, do not leave pots, pans or fryers unattended. Never leave an electric grill unattended when grilling. Fat and debris deposits impair the proper functioning of the ventilation hood. To ensure that cooking vapors are properly cleaned, never use the ventilation hood without the grease filters in place.
IMPORTANT SAFETY INSTRUCTIONS Proper installation WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: – a) Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. – b) Sufficient air is needed for combustion and exhausting of gases through the flue (chimney of fuel burning equipment to prevent back drafting.
IMPORTANT SAFETY INSTRUCTIONS Be sure to observe the information contained in the "Installation" section when mounting the ventilation hood. When installing the exhaust duct, only use pipes or tubes made of non-flammable material. These can be obtained from your Miele dealer or from Miele Technical Service. Exhaust air should not be vented into a chimney or vent flue which is otherwise in use and should not be channeled into ducting which ventilates rooms with fuel-burning installations.
IMPORTANT SAFETY INSTRUCTIONS Cleaning and care Never use a steam cleaner to clean the ventilation hood. The steam can reach the electrical components and cause a short circuit. Accessories Use only genuine original Miele parts. If parts or accessories from other manufacturers are used, the warranty will become void. FCC Declaration of Conformity These devices comply with FCC Rules Part 15.
Caring for the environment Disposal of the packing material The cardboard box and packing materials protect the appliance during shipping. They have been designed to be biodegradable and recyclable. Ensure that any plastic wrappings, bags, etc. are disposed of safely and kept out of the reach of children. Danger of suffocation! Disposal of your old appliance Do not dispose of this appliance with your household waste. Old appliances may contain materials that can be recycled.
Description of functions The following functions are available on your ventilation hood, depending on the model: Vented mode The air is drawn in and cleaned by the grease filters and directed outside. Non-return flap A non-return flap in the ducting prevents the exchange of inside and outside air from occurring when the ventilation hood is not in use. The flap is closed when the ventilation hood is turned off.
Description of functions Con@ctivity 2.0 function Automatic control This hood features a communication function which enables the automatic control of the hood based on the operational status of a Miele cooktop. The cooktop transmits information about its operational status to the hood using a radio signal. – When a burner is turned on, the cooktop lighting on the hood turns on automatically. After a brief delay, the ventilation hood fan also comes on.
Guide to the appliance 16
Guide to the appliance a Chimney extension b Chimney c Canopy d Control panel e Grease filters f Recirculation vent (only for recirculation mode) g Glass edge lighting h LED cooktop lighting i OdorFree Charcoal Filter optional accessory for recirculation mode j On/Off button for glass edge lighting k Button for cooktop lighting l On/Off button for fan m Buttons for setting the fan power n Button for Delayed shut down o Filter saturation indicator p Color change button 17
Operation (Automatic mode) When Con@ctivity 2.0 is active, the hood always operates in Automatic mode (see "Activating Con@ctivity 2.0"). See "Cooking without Con@ctivity 2.0" for information on manually operating the hood. Cooking with Con@ctivity 2.0 (Automatic mode) Turn on a burner to the desired power setting. The hood lighting will come on. After a few seconds, the fan will come on, briefly operating at power level 2 before immediately switching to level 1.
Operation (Automatic mode) Cooking process Turning off If, for example, you switch on a burner at the highest power setting to heat cookware in preparation for searing and then reduce the power level after approx. 60 to 90 seconds*, a cooking process is recognized. Turn off all burners. The hood turns on automatically and, after the cooktop power level has been reduced, switches back to fan level 3, where it remains for approx. 5 minutes.
Operation (Automatic mode) Temporarily exiting Automatic mode To temporarily exit the Automatic mode when cooking: Manually select a different fan level, or Manually turn the hood off, or Activate the Delayed shut down function on the ventilation hood. The fan turns off after the delay time selected, and the lighting will remain on. The ventilation hood functions can now be operated manually (see "Cooking without Con@ctivity 2.0").
Operation (Manual mode) Cooking without Con@ctivity 2.0 (Manual mode) Selecting the Delayed shut down time The hood can be operated manually if: It is a good idea to let the fan run for a few more minutes after cooking in order to neutralize any lingering vapors and odors in the air. With the Delayed shut down function, it is possible to have the fan automatically shut off after a predetermined period of time. – The Con@ctivity 2.0 function is not activated.
Operation (Manual mode) Turning cooktop lighting On/Off The cooktop lighting can be turned on and off separately from the fan. If power management is switched on, the 1 and IS indicators will be continuously lit. If it is turned off, 1 and IS will flash. To do so, press the button. Press the "" button to turn power management off. The symbol is lit when the cooktop lighting is turned on. The 1 and IS indicators will flash. Power management The 1 and IS indicators are constantly lit.
Operation (Automatic and Manual modes) Glass edge lighting Turning on the glass edge lighting The glass edge lighting can be turned on and off separately from the fan and the cooktop lighting. Pressing the Glass edge lighting button turns on the backlighting for the glass edge. Changing the color of the glass edge lighting The color of the glass edge lighting can be changed as desired. The color is preset to white. Turn on the glass edge lighting .
Operation (Automatic and Manual modes) Filter saturation indicator The number of hours the hood has been in operation is stored in appliance memory. The filter saturation indicators show when the filters need to be cleaned or changed by lighting up the grease filter symbol or OdorFree Charcoal Filter symbol . Additional information on cleaning and changing the filters and resetting the filter saturation counters can be found under "Cleaning and care.
Operation (Automatic and Manual modes) Activating/changing the grease filter saturation counter The OdorFree Charcoal Filter is required for recirculation mode. The filter saturation counter for the OdorFree Charcoal Filter requires onetime activation and must be set to match your cooking habits. Press the On/Off button to turn the fan off. Press the "" symbol and the filter saturation indicator at the same time.
Cleaning and care WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before cleaning or servicing the hood, disconnect it from the power supply, see "IMPORTANT SAFETY INSTRUCTIONS". Stainless steel housing General The surfaces and control buttons are susceptible to scratching and chipping. Observe the following cleaning instructions. Clean all surfaces and control buttons using warm water and liquid dish soap only, applying the mixture with a sponge cloth.
Cleaning and care Special instructions for control buttons Do not leave dirt and debris on the buttons for any length of time. Otherwise they may become discolored or damaged. Remove any dirt or debris immediately. Observe the general cleaning instructions contained in this chapter. Do not use a stainless steel cleaner to clean the control buttons. Special instructions for the glass edge In addition to the general cleaning options, the glass edge can also be cleaned using a household glass cleaner.
Cleaning and care Cleaning the grease filters in the dishwasher Place the filters as upright or inclined as possible in the lower basket. Ensure that the spray arm is not obstructed. Use a common household dishwasher detergent. To remove a grease filter, release the locking clip. Then, open the filter to a 45° angle, unhook it, and remove it from the hood. Cleaning the grease filters by hand Clean the filters with a soft nylon brush in a mild solution of hot water and dish soap.
Cleaning and care Reinstall the grease filters. When inserting the filters, make sure that the locking clip is facing down. OdorFree Charcoal Filter If the hood is equipped for recirculation, an OdorFree Charcoal Filter must be installed in addition to the grease filters. This filter is designed to absorb odorcausing agents and is mounted in the canopy above the grease filters. OdorFree Charcoal Filters are available from your Miele dealer or from Miele.
Cleaning and care When to change the OdorFree Charcoal Filter Always replace the OdorFree Charcoal Filter whenever it no longer absorbs kitchen odors effectively. Replace the filter at least once every 6 months. The OdorFree Charcoal Filter saturation counter will light up to remind you to change the charcoal filter regularly. The OdorFree Charcoal Filter saturation counter requires one-time activation before use (see the "Operation" chapter).
Installation Before installation Before installing the appliance, read all of the information contained in this chapter and also in the "IMPORTANT SAFETY INSTRUCTIONS" section. Removing the protective film Disassembly If the device ever needs to be disassembled, follow the installation sheet instructions in reverse order. A lever is provided to assist with the removal of the chimney. Unscrew the two mounting screws on the chimney.
Installation Installation parts 32
Installation a 3 protective installation sheets for use when installing the chimney b 1 exhaust connector for an exhaust duct 6" (150 mm). c 1 reducer for an exhaust duct 5" (125 mm). d 1 non-return flap for installation in the outlet duct collar of the motor unit (not for recirculation mode). Depending on the device version, the non-return flap is already mounted. e Telescopic wall bracket for securing the hood on the wall.
Installation Appliance dimensions The drawing is not to scale.
Installation a Extraction b Recirculation c Air vent positioned at top for recirculation de Mounting area (only d is required for recirculation ventilation hoods). Wall and ceiling area for exhaust duct opening and for wall socket installation. Only the wall socket installation is required for recirculation hoods. Vent collar 6" (150 mm), with adapter 5" (125 mm).
Installation Minimum distance S Cooking appliance Miele appliance Non-Miele appliance Electric/Induction cooktop 24" (610 mm) Electric grill, deep fat fryer (electric) 26" (660 mm) Multi-burner gas cooktop ≤ 43,000 BTU/hr (12.6 W), no burner > 15,000 BTU/hr (4.5 kW). 26" (660 mm) 30" (760 mm) Multi-burner gas cooktop ≤ 73,800 BTU/hr (21.6 W), no burner > 16,500 BTU/hr (4.8 kW) 30" (760 mm) Multi-burner gas cooktop > 73,800 BTU/hr (21.6 W), or one of the burners > 16,500 BTU/hr (4.
Installation Installation recommendations – We also recommend a distance of at least 25 1/2" (650 mm) above electric cooktops to provide more workspace and easier cooking under the hood. Drilling diagram for wall mounting When drilling, please follow the directions contained on the accompanying installation sheet. – When selecting an installation height, always take the user height into consideration.
Installation Plywood backing The majority of the weight of the installed ventilation system will be supported by the lower retaining plate. It must be firmly attached to the stud framing behind the drywall. If studs are not available in the required locations, a plywood backing (min. ½" (13 mm) thick) spanning at least two studs must be installed. Failure to adequately support the weight as stated may result in the ventilation system falling off the wall, causing personal injury and property damage.
Exhaust duct WARNING: Danger of toxic fumes. Gas cooking appliances release carbon monoxide that can be harmful or fatal if inhaled. To reduce the risk of fire and to properly exhaust air, the exhaust gases extracted by the hood should be vented outside of the building only. Do not vent exhaust air into spaces within walls or ceilings or in attics, crawl spaces or garages. To reduce the risk of fire, only use metal ductwork.
Exhaust duct Condensate trap Reducing Collar (optional accessory) In addition to insulating the exhaust duct, we recommend installing a condensate trap to collect and evaporate any condensate which might accumulate. Condensate traps are available for exhaust ducts with a diameter of 5" (125 mm) or 6" (150 mm). When installing a condensate trap, make sure that it is positioned vertically and, if possible, directly above the hood outlet duct collar.
Electrical connection WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: All electrical work should be performed by a qualified electrician in strict accordance with national regulations (for USA: ANSI-NFPA 70) and local safety regulations. Installation, repairs and other work by unqualified persons could be dangerous. Ensure that power to the appliance is OFF while installation or repair work is performed.
Activating Con@ctivity 2.0 Activating Con@ctivity 2.0 To use the Con@ctivity 2.0 function, the radio link between the cooktop and the hood must be activated. Both appliances must be installed and operational. The hood begins searching for a radio connection. Indicator 2 is continuously lit, and the indicator 3 flashes. As this is happening, begin activation on the cooktop. Activating the cooktop You only need to carry out the activation procedure once.
Activating Con@ctivity 2.0 If Con@ctivity 2.0 has been activated, the indicators for levels 2 and 3 will be constantly lit. If Con@ctivity 2.0 has not been activated, the indicators for levels 2 and 3 will flash simultaneously. To exit the check, press the Delayed shut down button 515. All indicators will go out. To check whether activation has taken place on the cooktop, please refer to corresponding operating instructions.
Service and warranty For faults that you cannot resolve on your own, please contact your Miele dealer or Miele Technical Service. The telephone number for the Technical Service Department is listed at the back of these instructions. When contacting Miele, please state the model and serial number of your ventilation hood. These can be found on the data plate. Location of the data plate The data plate is visible once you have removed the grease filters.
Technical data Fan motor LED cooktop lighting Glass edge lighting Total connected load Voltage, frequency Fuse rating Power cord length Weight 350 W 3x3W 10 W 369 W 120 V AC, 60 Hz 15 A 6.5 ft (2 m) 59 lbs (27 kg) Optional accessories for recirculation mode: Recirculation kit DUW 20 and OdorFree Charcoal Filter DKF 12 Contains FCC ID: 2ACUWEI8800 IC: 5669C-EI8800 This device complies with Part 15 of the FCC Rules and with Industry Canada licence-exempt RSS standard(s).
Please have the model and serial number of your appliance available before contacting Technical Service. U.S.A. Canada Miele, Inc. Importer Miele Limited National Headquarters 9 Independence Way Princeton, NJ 08540 Phone: 800-843-7231 609-419-9898 609-419-4298 Fax: www.mieleusa.com Technical Service & Support Nationwide Phone: 800-999-1360 888-586-8056 Fax: TechnicalService@mieleusa.com Headquarters and Miele Centre 161 Four Valley Drive Vaughan, ON L4K 4V8 www.miele.
DA 6296 W en-US M.-Nr.