Operating and installation instructions SmartLine downdraft extractor To avoid the risk of accidents or damage to the appliance it is essential to read these instructions before it is installed and used for the first time. en-GB M.-Nr.
Contents Warning and Safety instructions...................................................................... 4 Caring for the environment .............................................................................. 14 Guide to the appliance ...................................................................................... Downdraft extractor............................................................................................. Controls and display ............................................
Contents Worktop cutout – flush-fit.................................................................................... Spacer bars – flush-fit ......................................................................................... Installation dimensions – Flush-fit ....................................................................... Air duct dimensions – flush-fit – worktop depth 600 mm ................................... Air duct dimensions – flush-fit – worktop depth greater than 600 mm ...........
Warning and Safety instructions This downdraft extractor complies with all relevant safety requirements. Inappropriate use can, however, lead to personal injury and material damage. Please read these operating and installation instructions carefully before using the downdraft extractor for the first time. They contain important information on safety, installation, use and maintenance. This prevents both personal injury and damage to the downdraft extractor.
Warning and Safety instructions Correct application This downdraft extractor is intended for use in domestic households and similar working and residential environments. The downdraft extractor is not suitable for outdoor use. It must only be used as a domestic appliance to extract vapours and remove odours from cooking. All other types of use are not permitted.
Warning and Safety instructions Safety with children Children under 8 years of age must be kept away from the countertop extractor unless they are constantly supervised. Children aged 8 and older may only use the countertop extractor without supervision if they have been shown how to use it in a safe manner. Children must be able to understand and recognise the possible dangers caused by incorrect operation. Children must not be allowed to clean or maintain the downdraft extractor unsupervised.
Warning and Safety instructions Technical safety Unauthorised installation, maintenance and repairs can cause considerable danger for the user. Installation, maintenance and repairs must only be carried out by a Miele authorised technician. The downdraft extractor must only be installed and operated in combination with those SmartLine elements and hob units specified by Miele. Damage to the downdraft extractor can compromise your safety. Check it for visible signs of damage.
Warning and Safety instructions Before connecting the downdraft extractor to the mains supply, ensure that the connection data on the data plate (voltage and frequency) match the mains electricity supply. This data must correspond in order to avoid the risk of damage to the downdraft extractor. Compare this data before connecting the appliance to the mains. Consult a qualified electrician if in any doubt.
Warning and Safety instructions If the mains connection cable is damaged, it must be replaced with a special mains connection cable by a qualified electrician (see “Electrical connection” in the “Installation” chapter). During installation, maintenance and repair work, the downdraft extractor must be completely disconnected from the mains electricity supply.
Warning and Safety instructions Using at the same time as other heating appliances that depend on the air from the room Danger of toxic fumes! Great care should be taken when using the downdraft extractor in the same room or the same area of the house as another heating appliance that depends on the air from the room. Such heating appliances draw in air from the room and duct exhaust gases out through a chimney or extraction ducting.
Warning and Safety instructions In order to ensure safe operation and to prevent gases given off by the heating appliance from being drawn back into the room, when the downdraft extractor and the heater are both operated simultaneously, an underpressure in the room of 0.04 mbar (4 Pa) is the maximum permissible. Sufficient ventilation can be maintained by air inlets which cannot be blocked, e.g. in windows, doors and outside wall vents. The diameter of the inlet openings must enable sufficient ventilation.
Warning and Safety instructions Correct use Open flames are a fire hazard. Never use an open flame beside the downdraft extractor. To avoid the danger of fire, do not flambé or grill over an open flame. When switched on, the downdraft extractor could draw flames into the filter. Fat deposits could ignite, presenting a fire hazard. Overheated oil and fat can ignite, causing fire damage to the downdraft extractor.
Warning and Safety instructions Cleaning and care The steam from a steam cleaning appliance could reach live electrical components and cause a short circuit. Do not use a steam cleaner to clean the downdraft extractor. There is a risk of fire if the cooker hood is not cleaned as described in these operating instructions. Miele will guarantee to supply functional spare parts for a minimum of 10 years and up to 15 years following the discontinuation of your CombiSet.
Caring for the environment Disposal of the packing material Disposing of your old appliance The packaging is designed to protect the appliance from damage during transportation. The packaging materials used are selected from materials which are environmentally friendly for disposal and should be recycled. Electrical and electronic appliances often contain valuable materials. They also contain specific materials, compounds and components, which were essential for their correct function and safety.
Guide to the appliance Downdraft extractor a Extraction grille b Grease filter c Cover with control unit d Casing e Removable drip tray f Air duct (supplied as accessory) g Fan In the plinth on the floor h E-box 15
Guide to the appliance Controls and display a Countertop extractor On/Off b Numerical display To set a power level 16
Guide to the appliance Accessories supplied The accessories supplied with your appliance as well as a range of optional ones are available to order from Miele (see “Optional accessories”). Air duct Flat ducting system for routing air from the casing to the fan.
How it works Extraction mode Recirculation mode The air is drawn in and cleaned by the grease filter and directed outside. (DUU 1000(-1) conversion kit required) 18 The air is drawn in and cleaned by the grease filter. The air is then directed into the recirculation box where it is also cleaned by the charcoal filters. The cleaned air is then recirculated back into the kitchen.
Cleaning the SmartLine element for the first time Please stick the extra data plate for the appliance supplied with this documentation in the space provided in the “After sales service” section of this booklet. Remove any protective wrapping and stickers. Clean the ceramic surface with a damp cloth, and then wipe dry.
Operation Switching the downdraft extractor on Switching the downdraft extractor off Touch the sensor control. The sensor controls go out. If the downdraft extractor is not switched off, it will switch itself off 12 hours after the last automatic operation. Insert the extraction grille. Run-on time Touch the sensor control. In order to rid kitchen air of steam and odours, the downdraft extractor continues to run for 5 minutes on the power level that was set last.
Tips on saving energy This downdraft extractor operates very efficiently and economically. The following will help you to save even more energy when using it: - It is important to ensure that the kitchen is well ventilated during operation. In extraction mode if there is insufficient air flow, the downdraft extractor cannot operate efficiently and this causes increased operating noise levels. - Always cook with the lowest possible setting.
Cleaning and care Danger of burning due to hot surfaces. The surfaces will be hot after cooking. Switch the countertop extractor and the cooking elements off. Allow the surfaces to cool down before cleaning the countertop extractor. Risk of damage due to moisture ingress. The steam from a steam cleaning appliance could reach live electrical components and cause a short circuit. Do not use a steam cleaner to clean the countertop extractor.
Cleaning and care Cleaning the ceramic surface Risk of damage by pointed objects. The seal between the SmartLine element and the worktop could suffer damage. Do not use pointed objects for cleaning. Not all soiling and residues can be removed using a solution of washing-up liquid. An invisible film can develop that can lead to discolouration of the glass ceramic surface. This discolouration cannot be removed. Clean the ceramic surface regularly with a proprietary ceramic glass cleaning agent.
Cleaning and care Grease filter/extraction grille The extraction grille and the reusable metal grease filter in the vapour extraction fan collect solid matter from kitchen vapours (grease, dust, etc.) and therefore prevent soiling of the downdraft extractor. Accumulated grease solidifies over a longer period of time and makes cleaning more difficult. The grease filter should therefore be cleaned at least every 3–4 weeks. Risk of fire due to soiled grease filter.
Cleaning and care Fitting the grease filter Fit the grease filter so that the straight side of the grease filter is on the side that connects to the air duct. Example: connector for air duct on the left Interior of the casing When removing the grease filter for cleaning, also clean off any accessible oil or fat build-up from the casing. Doing so will prevent a fire hazard.
Problem solving guide Many malfunctions and faults that can occur in daily operation can be easily remedied. Time and money will be saved because a service call will not be needed. The following guide may help you to find the reason for a malfunction or a fault, and to correct it. Problem Cause and remedy The power levels 1 to B light up one after the other. An automatic reset is performed after an interruption to the power supply. The SmartLine element cannot be switched on.
Optional accessories Miele offer a comprehensive range of useful accessories as well as cleaning and conditioning products for your Miele appliances. FlameGuard These products can be ordered through the Miele Webshop. They can also be ordered from Miele (see end of this booklet for contact details) or from your Miele dealer.
After sales service Contact in the event of a fault In the event of any faults which you cannot remedy yourself, please contact your Miele dealer or the Miele Customer Service Department. You can book a Miele Customer Service Department call-out online at www.miele.com/service. Contact information for the Miele Customer Service Department can be found at the end of this document. Please quote the model identifier and serial number of your appliance (Fabr./SN/ Nr.
*INSTALLATION* Installation Safety instructions for installation Damage risk from incorrect installation. Incorrect installation can cause damage to the SmartLine element. The SmartLine element must only be installed by a qualified person. Damage from falling objects. Take care not to damage the SmartLine element when fitting wall units above it. Fit the wall units before the SmartLine element.
*INSTALLATION* Installation Installation examples Recirculation mode Extraction mode 30
*INSTALLATION* Installation Installation notes – surface-mounted Tiled worktop Sealing between the SmartLine Element and the worktop The SmartLine element and worktop may be damaged if the element needs to be removed after it has been sealed with a sealant. Do not use any sealant between the SmartLine element and the worktop. The seal under the edge of the top part of the appliance provides a sufficient seal for the worktop.
*INSTALLATION* Installation Installing several SmartLine elements The gaps between the individual SmartLine elements are sealed with a silicone sealant that is heat-resistant to at least 160 °C. With flush-fit installation, the gap between the SmartLine element(s) and the worktop must also be sealed with a silicone sealant that is heat-resistant to at least 160 °C.
*INSTALLATION* Installation Worktop cutout – surface-mounted 33
*INSTALLATION* Installation Installation with a countertop extractor Combination examples 34 Number x width [mm] Dimension B [mm] Cooking elements Countertop extractor 1 x 378 1 x 120 481 2 x 378 1 x 120 862 1 x 378 1 x 620 2 x 120 1226 3 x 378 2 x 120 1365 2 x 378 1 x 620 2 x 120 1607 4 x 378 2 x 120 1746 1 x 620 2 x 120 845
*INSTALLATION* Installation Installation without a countertop extractor Combination examples Number x width [mm] Cooking elements Dimension B [mm] 1 x 378 359 2 x 378 740 1 x 378 1 x 620 982 3 x 378 1121 2 x 378 1 x 620 1363 4 x 378 1502 2 x 378 1 x 800 1554 2 x 378 1 x 936 1680 35
*INSTALLATION* Installation Spacer bars – surface-mounted If you are installing several appliances, you must fit spacer bars between them. The clips supplied with the spacer bars are only required for installing a CSDA 700x FL.
*INSTALLATION* Installation Installation dimensions – Surface-mounted All dimensions are given in mm.
*INSTALLATION* Installation Air duct dimensions – surface-mounted – worktop depth 600 mm Side view 38
*INSTALLATION* Installation a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting. b After installation the removable drip tray must be accessible. 2 quick-release catches have to be opened at the front and rear to remove the tray. c Duct length must be adapted to the height of the base unit.
*INSTALLATION* Installation Front view View from above 40
*INSTALLATION* Installation Air duct dimensions – surface-mounted – worktop depth greater than 600 mm View from the side – right air duct connection 41
*INSTALLATION* Installation a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting. b Duct connecter, adapted to the worktop depth c After installation the removable drip tray must be accessible. 2 quick-release catches have to be opened at the front and rear to remove the tray. d Duct length must be adapted to the height of the base unit.
*INSTALLATION* Installation View from the front – right air duct connection View from above – right air duct connection 43
*INSTALLATION* Installation If you want to install the air duct to the left of the downdraft extractor, the worktop must be at least 665 mm deep.
*INSTALLATION* Installation Installation – surface-mounted Wooden worktops If the worktop is more than 24 mm deep, it must be cut out underneath on the building-in side on the right or left hand side. Fit the bracket so that it sits flush with the top edge of the worktop cutout. a Worktop b Maximum 24 mm c 12 mm Secure the bracket with the 3.5 x 25 mm wood screws supplied. Natural stone worktops You will need heavy-duty doublesided tape (not supplied) to secure the bracket.
*INSTALLATION* Installation Preparing the worktop Wooden worktops Create the worktop cutout. Remember to maintain the minimum safety distances (see “Installation – Safety distances”). Seal any cut surfaces on wooden worktops with a special varnish, silicone sealant or resin to prevent the wood from swelling as a result of moisture ingress. The sealant must be heat-resistant. Make sure that the sealant does not come into contact with the top of the worktop.
*INSTALLATION* Installation Installing the countertop extractor The countertop extractor can be installed with the connector for the air duct on either the right or the left-hand side. Remove the grease trap from the casing. a Connector for air duct on the right b Connector for air duct on the left Stick the sealing strip supplied under the edge of the cover. Do not apply the sealing strip under tension.
*INSTALLATION* Installation Installing the air duct Mount the air duct. Length compensation – worktop depth 600 mm Length compensation does not fit. The duct piece must be at least 100 mm long. Divide the flat ducting into 2 pieces to suit your installation situation. The upper piece must have a minimum length of 100 mm. If the exhaust ducting does not sit securely up against the exhaust duct connection, stick the sealing strip supplied to the exhaust duct connection.
*INSTALLATION* Installation Length compensation – worktop depth greater than 600 mm Installing the fan motor Divide the flat ducting into 2 pieces. 1 piece must correspond to the difference between 600 mm and the worktop depth. a Sealing strip Stick the sealing strip supplied to the fan connection. Insert the duct piece into the horizontal bend. Connect the duct piece with the short bend . Fix the connection with the sealing strip.
*INSTALLATION* Installation E-box Connection to window contact, if required The window contact connection a Mains connection cable b Connection to window contact c Electrical connection socket for the fan operating voltage cable d Electrical connection socket for the fan control cable e Electrical connection socket for the control unit cable 50 is live! Danger of electric shock! Disconnect the countertop extractor from the mains before connecting the switching system.
*INSTALLATION* Installation Loosen the lug and pull the plug out. Connecting the e-box Connect the operating voltage and fan control cables to the e-box and the fan. Connect the control unit cable to the e-box. The socket positions are designed in such a way that they cannot be mixed up. Loosen the strain relief screw and unlock the casing on both sides . Open the casing. Remove the stopper. Connect the downdraft extractor to the mains. Check that the downdraft extractor works.
*INSTALLATION* Installation Installation notes – flush-fit Flush-fit installation is only possible in natural stone (granite, marble), solid wood and tiled worktops. For installation in worktops made of other materials, please consult the relevant manufacturer as to whether their worktops are suitable for flush-fit installation.
*INSTALLATION* Installation Installing several SmartLine elements The gaps between the individual SmartLine elements are sealed with a silicone sealant that is heat-resistant to at least 160 °C. With flush-fit installation, the gap between the SmartLine element(s) and the worktop must also be sealed with a silicone sealant that is heat-resistant to at least 160 °C.
*INSTALLATION* Installation Worktop cutout – flush-fit 500 + 1 524 +1 0 50 A +1 B +1 ßR4 5,5+ 0,5/ 7+ 0,5 * 02 12 +1 B A +1 Natural stone worktop * 7+0.
*INSTALLATION* Installation Installation with a countertop extractor Combination examples Number x width [mm] Dimension A [mm] Dimension B [mm] Cooking elements Countertop extractor 1 x 378 1 x 120 505 481 2 x 378 1 x 120 886 862 1 x 378 1 x 620 2 x 120 1250 1226 3 x 378 2 x 120 1389 1365 2 x 378 1 x 620 2 x 120 1631 1607 4 x 378 2 x 120 1770 1746 1 x 620 2 x 120 869 845 55
*INSTALLATION* Installation Installation without a countertop extractor Combination examples Number x width [mm] Dimension A [mm] Dimension B [mm] 1 x 378 383 359 2 x 378 764 740 1 x 378 1 x 620 1006 982 3 x 378 1145 1121 2 x 378 1 x 620 1387 1363 4 x 378 1526 1502 2 x 378 1 x 800 1567 1543 2 x 378 1 x 936 1703 1679 Cooking elements 56
*INSTALLATION* Installation Spacer bars – flush-fit If you are installing several appliances, you must fit spacer bars between them. The clips supplied with the spacer bars are only required for installing a CSDA 700x FL.
*INSTALLATION* Installation Installation dimensions – Flush-fit All dimensions are given in mm.
*INSTALLATION* Installation Air duct dimensions – flush-fit – worktop depth 600 mm Side view 59
*INSTALLATION* Installation a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting. b After installation the removable drip tray must be accessible. 2 quick-release catches have to be opened at the front and rear to remove the tray. c Duct length must be adapted to the height of the base unit.
*INSTALLATION* Installation Front view View from above 61
*INSTALLATION* Installation Air duct dimensions – flush-fit – worktop depth greater than 600 mm View from the side – right air duct connection 62
*INSTALLATION* Installation a For maintenance work it must be possible to remove the rear cabinet wall. The cabinet wall and an adjoining room wall or a piece of furniture must be at least 110 mm apart to ensure sufficient room for the ducting. b Duct connecter, adapted to the worktop depth c After installation the removable drip tray must be accessible. 2 quick-release catches have to be opened at the front and rear to remove the tray. d Duct length must be adapted to the height of the base unit.
*INSTALLATION* Installation View from the front – right air duct connection View from above – right air duct connection 64
*INSTALLATION* Installation If you want to install the air duct to the left of the downdraft extractor, the worktop must be at least 665 mm deep.
*INSTALLATION* Installation Installation – flush-fit Wooden worktops If the worktop is more than 28 mm deep, it must be cut out underneath on the building-in side on the right or left hand side. Fit the bracket so that it sits flush with the top edge of the lower step of the stepped cutout. a Worktop b Maximum 24 mm c 12 mm Secure the bracket with the 3.5 x 25 mm wood screws supplied. Natural stone worktops You will need heavy-duty doublesided tape (not supplied) to secure the bracket.
*INSTALLATION* Installation Preparing the worktop Wooden worktops Create the worktop cutout. Remember to maintain the minimum safety distances (see “Installation – Safety distances”). Seal any cut surfaces on wooden worktops with a special varnish, silicone sealant or resin to prevent the wood from swelling as a result of moisture ingress. The sealant must be heat-resistant. Make sure that the sealant does not come into contact with the top of the worktop.
*INSTALLATION* Installation Installing the countertop extractor The countertop extractor can be installed with the connector for the air duct on either the right or the left-hand side. Remove the grease trap from the casing. a Connector for air duct on the right b Connector for air duct on the left Stick the sealing strip supplied under the edge of the cover. Do not apply the sealing strip under tension. Fit the clips onto the spacer bars.
*INSTALLATION* Installation Installing the air duct Mount the air duct. Length compensation – worktop depth 600 mm Length compensation does not fit. The duct piece must be at least 100 mm long. Divide the flat ducting into 2 pieces to suit your installation situation. The upper piece must have a minimum length of 100 mm. If the exhaust ducting does not sit securely up against the exhaust duct connection, stick the sealing strip supplied to the exhaust duct connection.
*INSTALLATION* Installation Length compensation – worktop depth greater than 600 mm Installing the fan motor Divide the flat ducting into 2 pieces. 1 piece must correspond to the difference between 600 mm and the worktop depth. a Sealing strip Stick the sealing strip supplied to the fan connection. Insert the duct piece into the horizontal bend. Connect the duct piece with the short bend . Fix the connection with the sealing strip.
*INSTALLATION* Installation E-box Connection to window contact, if required The window contact connection a Mains connection cable b Connection to window contact c Electrical connection socket for the fan operating voltage cable d Electrical connection socket for the fan control cable e Electrical connection socket for the control unit cable is live! Danger of electric shock! Disconnect the countertop extractor from the mains before connecting the switching system.
*INSTALLATION* Installation Loosen the lug and pull the plug out. Connecting the e-box Connect the operating voltage and fan control cables to the e-box and the fan. Connect the control unit cable to the e-box. The socket positions are designed in such a way that they cannot be mixed up. Loosen the strain relief screw and unlock the casing on both sides . Open the casing. Remove the stopper. Connect the downdraft extractor to the mains. Check that the downdraft extractor works.
*INSTALLATION* Installation Ducting If the downdraft extractor is used at the same time as a heating appliance that relies on oxygen from the same room, there is a risk of toxic fumes. It is essential that the “Warning and Safety” instructions are observed. The downdraft extractor should be installed according to local and national building regulations. Seek approval from the building inspector where necessary. The downdraft extractor has an exhaust connection of 222 x 89 mm.
*INSTALLATION* Installation Electrical connection The SmartLine element is supplied with a mains cable with moulded plug ready for connection to a suitable earthed socket. The socket must be easily accessible after the SmartLine element has been installed. If the socket is not easily accessible, ensure that a suitable means of disconnection is provided on the installation side for each pole. Risk of fire from overheating.
Product data sheets The following data sheets apply to the models described in this operating instruction manual. Data sheet for household cooker hoods In acc. with delegated regulation (EU) No. 65/2014 and regulation (EU) No.
United Kingdom Miele Co. Ltd., Fairacres, Marcham Road, Abingdon, Oxon, OX14 1TW Tel: 0330 160 6600, Internet: www.miele.co.uk/service, E-mail: info@miele.co.uk Australia Miele Australia Pty. Ltd. ACN 005 635 398 ABN 96 005 635 398 1 Gilbert Park Drive Knoxfield, VIC 3180 Tel: 1300 464 353 Internet: www.miele.com.au China Mainland Miele Electrical Appliances Co., Ltd. 1-3 Floor, No. 82 Shi Men Yi Road Jing' an District 200040 Shanghai, PRC Tel: +86 21 6157 3500 Fax: +86 21 6157 3511 E-mail: info@miele.