Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Caring for the environment
- Installation
- Installation location
- Installation notes
- Specifications for the plumbed water connection
- Installation dimensions
- Dimensions of the cabinet front
- Building in the appliance
- Before starting...
- Tools required
- Weight of cabinet front
- Aligning the installation niche
- Checking the installation niche
- Before installation
- Preparing the installation niche
- Pushing the appliance into the niche
- Aligning the refrigeration appliance
- Securing the appliance in the niche
- Preparing the cabinet fronts
- Securing and aligning the cabinet front
- Mounting the fixing brackets
- Securing the covers
- Mounting the cover in a side-by-side combination
- Securing the toe-kick ventilation grille and toe-kick cover
- Water connection
- Electrical connection
- Saving energy
- Guide to the appliance
- Accessories
- Before first use
- Switching on and off
- Selecting additional settings
- The correct temperature
- Using SuperFrost
- Temperature and door alarm
- Adjusting the interior fittings
- Freezing and storing food
- Making ice cubes
- Automatic defrosting
- Cleaning and care
- Water filter
- Frequently Asked Questions
- Causes of noises
- Customer Service
- Declaration of conformity
- Copyrights and licenses
Installation
*INSTALLATION*
36
Adjust the front feet with a ratchet (at-
tachment: 5/16” (8mm) socket) or a
TX20 screwdriver .
Tip: Proceed carefully when adjusting
the feet, alternating between the left
and right feet.
Place a level across the installation
aids on the appliance door to
check the refrigeration appliance’s
alignment.
Unscrew the feet and on both
sides at least until the marking on the
toe-kick is aligned with the required
1 1/4” (32mm) on the spacer . The
standard dimension of 1 1/4” (32mm)
relates to a niche height of
84” (2,134mm).
It is important to adjust the feet to a
height of at least 1 1/4” (32mm) so
that the ventilation of the refrigeration
appliance via the toe-kick functions
correctly.
Risk of damage if the feet are
adjusted too much.
The rear adjustable feet can be dam-
aged.
Unscrew the feet only until the
marking on the toe-kick is aligned to
a maximum of 2 7/16” (62mm) (max.
niche height of 85 3/16” (2,164mm)).