Operating and Installation instructions
Table Of Contents
- Contents
- IMPORTANT SAFETY INSTRUCTIONS
- Notes on installation
- All Gas Range dimensions
- All Electric Range dimensions
- Dual Fuel Range dimensions
- HR 1724-3 DF
- Detailed views of HR 1724-3 DF
- HR 1924-3 DF
- Detailed views of HR 1924-3 DF
- HR 1934-3 DF, HR 1935-3 DF, HR 1936-3 DF
- Detailed views of HR 1934-3 DF
- Detailed views of HR 1935-3 DF
- Detailed views of HR 1936-3 DF
- HR 1954-3 DF, HR 1955-3 DF, HR 1956-3 DF
- Detailed views of HR 1954-3 DF
- Detailed views of HR 1955-3 DF
- Detailed views of HR 1956-3 DF
- Anti-tip device
- Plumbed water connection
- Electrical connection
- Gas connection
- Burner ratings
- Burner ratings HR 1124-3 AG
- Burner ratings HR 1134-3 AG
- Burner ratings HR 1135-3 AG
- Burner ratings HR 1136-3 AG
- Burner ratings HR 1724-3 DF
- Burner ratings HR 1924-3 DF
- Burner ratings HR 1934-3 DF
- Burner ratings HR 1935-3 DF
- Burner ratings HR 1936-3 DF
- Burner ratings HR 1954-3 DF
- Burner ratings HR 1955-3 DF
- Burner ratings HR 1956-3 DF
- Customer Service
- Caring for the environment
- Copyrights and licenses
- Copyrights and licenses for the communication module
Burner ratings
*INSTALLATION*
Burner ratings HR1136-3AG
Natural gas NG Btu/hr kW
Simmer burner 8,000 2.3
Power burner, rear 9,000 2.6
Power burner, front 19,500 5.7
Griddle plate 13,000 3.8
Browning burner 22,000 6.4
Bake burner 25,500 7.5
Total cooktop output 69,000 20.2
Maximum total output of Range 94,500 27.7
Liquid propane LP Btu/hr kW
Simmer burner 8,000 2.3
Power burner, rear 9,000 2.6
Power burner, front 19,500 5.7
Griddle plate 13,000 3.8
Browning burner 20,150 5.9
Bake burner 27,500 8.1
Total cooktop output 69,000 20.2
Maximum total output of Range 96,500 28.3
111